JUDO QUICKSOFT-UNO
9
Installation
4.
Installation
4.1
General
ATTENTION
(see chapter on “Safety information and
dangers due to non-compliance”)
The unit may only be installed by skilled per-
sonnel.
The chapter on “Intended Use” must always
be observed!
The pipes must be able to safely support the
Softener.
Otherwise mechanical damage or fractures/
bursts can occur in the pipes. This can result
in major water damage. People close to the
Softener are exposed to a health risk due to
the large quantities of water released.
Therefore, if necessary, the pipes must be
additionally fixed or supported.
Always observe the given spacings to en-
sure convenient operation and servicing
(see chapter on “Installed dimensions”)
A clearance of at least 300 mm is required
above the Softener in order to be able to
properly carry out all maintenance and serv-
icing work.
(see chapter on “Modifications / changes /
spare parts”)
4.1.1 Requirements for the place of
installation
The room where the unit is installed must
be dry and frost free!
Unauthorised persons must not have ac-
cess to the Softener!
ATTENTION
(see chapter on “Safety information and
dangers due to non-compliance”)
–
The ambient temperature must not ex-
ceed 30°C (86°F)!
–
In order to be able to safely discharge
the wastewater (regeneration) in opera-
tion and in case of any defects that occur
in the system, precise compliance with
the details given in the “Installation”
chapter is necessary!
–
If the wastewater cannot be safely and
completely discharged, the house and
installations can be damaged by water.
–
A shut-off valve must be installed up-
stream and downsteam of the Softener
with a bypass to allow continued water
supply when the Softener is out of serv-
ice! This enables the water supply to the
Softener to be interrupted during instal-
lation, servicing/maintenance, repairs
and in case of malfunctions. Floods and
serious water damage to house installa-
tions can therefore be avoided.
–
The unit can be installed in all standard
drinking water pipes.
–
It is not permitted to install the Softener
upstream of the
water meter!
A power connection (230 V, 50
Hz), which is permanently live,
must be available.