JUDO PURE@TAP
9
Installation
1.1
Faucet
1.2
Escutcheon with O-ring
1.3
Rubber washer
1.4
Locating washer
1.5
Star washer
1.6
Hexagon nut
1.7
Hose adaptor 7/16"-24 UNS
4.1.4 Mounting of the fresh water
supply line
All the lines connected with this device
may only be mounted on cold water
lines.
–
Close the water supply at the angle
valve (see fig. 8).
–
Mount the angled inlet valve tightly on
this angle valve.
–
Mount the hose adaptor on the angled
inlet valve.
4.1.5 Installation of the under-sink
water filter
Hang the under-sink water filter into the wall
holder.
Pay attention to the flow direction (see
fig. 6)!
Mount both hose adaptors on the under-sink
water filter.
Connect the under-sink water filter via the
hoses with the angled inlet valve and the
faucet.
The hoses have accordingly to be cut short.
Open carefully the cold water line and the
faucet so that the air can escape from the
system. The microfiltration module must al-
so be vented via the bleed screw. The bleed
screw must be slightly unscrewed so that
the air can escape. Retighten the bleed
screw (see fig. 7).
It has to be flushed till the clear water will run
off.
Re-close the faucet.
Fig. 5:
Robinet avec kit de raccordement
1.1
1.2
1.3
1.4
1.5
1.6
1.7
Fig. 6:
Flow direction