Technical data
16
JUDO JPF+
1701582 • 2018/12
7.1
Installation dimensions
Fig.:
JPF+ ¾" - 1¼"
JPF+ ¾"
JPF+ 1"
JPF+ 1¼"
A 180
195
230
B 130
130
130
C 280
280
280
D 165
165
165
E 165
165
170
F 100
100
105
G 40
40
40
G1 14
14
14
A Installation length
B Unit depth
C Height above the pipe middle
D Height below the pipe middle
E Installation depth up to the pipe middle
F Waste water connection up to the pipe
middle
G Waste water nominal diameter
G1 Waste water nominal diameter (alterna-
tive)
7.2
Accessories
•
Expansion QUICKSET JQR (order no.
8250041) for series connection of two
devices, e.g. filter and water treatment
plant
•
PRO-SAFE leak protection (order
no. 8140011)
•
Safety block JSB (Best.-Nr. 8735260)
for retrofitting the filter with pressure
reducer, non-return valve, inlet and out-
let pressure manometer