background image

Product information

1701582 • 2018/12

JUDO JPF+  

7

Fig. 1:

Functional description

1

Reset key

2

Handwheel lid with battery compartment for backwash reminder alarm

3

Handwheel for backwashing

4

Adjusting ring for the next backwash date

5

Transparent filter hood

6

Built-in rotary flange

7

Backwashing valve

2.3

Materials used

The materials used are resistant to the

physical, chemical and corrosive loads

expected to be encountered in drinking

water. They meet the requirements speci-

fied in the following standards: 

DIN EN 13443-1

DIN 19628

DIN 50930-6

All materials are hygienically and physi-

ologically harmless and fulfill the require-

ments and directives of the Umweltbunde-

samt (UBA). Plastics fulfil the requirements

of DIN EN 16421.

2.4

Approval marks

The device complies with the technical

regulations for drinking water installation

according to DIN EN 806ff. and the national

Summary of Contents for PROFI-PLUS JPF+ 1"

Page 1: ...rotective filter 1 Valid for EU countries and Switzerland Language English Read before use and store Installation and operating instructions JUDO PROFI PLUS Backwash protective filter 1 Valid for EU countries and Switzerland Language English Read before use and store ...

Page 2: ...nden All rights reserved Reprinting even in excerpt form is only permitted with special approval Dear customers Thank you for the confidence you have shown in us by purchasing this prod uct You have purchased a state of the art device It has been carefully checked prior to delivery Nevertheless if diffi culties occur please contact the closest customer service see chapter Customer service These in...

Page 3: ... 8 3 2 Installation of the rotary flange fit ting 8 3 3 Installation of the device 9 3 4 Draining of the backwash water 10 3 5 Commissioning 11 4 Operation 11 4 1 Cleaning of the sieve insert backwash ing 11 4 2 Conversions changes 12 4 3 Maintenance repair spare parts 13 4 4 Temporary removal of the device 13 5 Servicing 13 5 1 Cleaning 13 5 2 Warranty and maintenance 13 6 Fault 14 7 Technical da...

Page 4: ...Application limits 1 2 1 Water quality The water to be filtered must comply with the European Drinking Water Directive Before using the device with water that does not comply with this Directive it is essential to consult the manufacturer 1 2 2 Water pressure CAUTION The water pressure must not exceed 16 bar input pressure The device must not be installed if the mains pressure is above 16 bar even...

Page 5: ... to installa tion Immediately have any malfunctions in operation rectified by qualified tech nical personnel Persons who due to their physical sen sory or mental abilities or their inexperi ence or lack of knowledge are unable to operate the device safely may not oper ate it without supervision or instruction from a responsible person Regular backwashing of the device is required to ensure safe dr...

Page 6: ...ts used Unit Conversion bar 1 bar 105 Pa 0 1 N mm2 DN 20 1 DN 25 1 DN 32 2 Product information 2 1 Scope of supply Backwash protective filter pre assem bled Rotary flange fitting 2 batteries see chapter 4 1 2 Installation and operating instructions 2 2 Function description Unfiltered water flows into the device through the rotary flange A coarse filter prevents large dirt particles from reaching t...

Page 7: ...ed are resistant to the physical chemical and corrosive loads expected to be encountered in drinking water They meet the requirements speci fied in the following standards DIN EN 13443 1 DIN 19628 DIN 50930 6 All materials are hygienically and physi ologically harmless and fulfill the require ments and directives of the Umweltbunde samt UBA Plastics fulfil the requirements of DIN EN 16421 2 4 Appr...

Page 8: ...tional fastenings or support To ensure convenient operation and main tenance of the device always adhere to the specified clearances in chapter 3 4 1 3 1 1 Requirements for the place of installation CAUTION The installation room must be dry and free from frost The ambient temperature must not exceed 30 C In higher temper atures or direct sunlight mater ial damage may occur up to and including brea...

Page 9: ...e installation of the device in domestic water piping only use the supplied built in rotary flange see chapter 3 2 The flange surface of the rotary flange fitting must be upright For proper sealing the profile of the profile flange seal must point towards the rotary flange fitting see Figure 2 1 2 Fig 3 Attach and engage appliance 1 Insert screws 2 Turn clockwise to engage screws Fig 4 Connection ...

Page 10: ...neath the filter is not possible the backwash water can be drained away via a hose or a pipe that is connected from the backwash ing water valve over a few meters to the closest waste water connection The dimen sioning of this pipe must correspond to the backwashing water valve If a bucket is used to drain off the back wash water Attention If the mains pressure is high water may spray out of the b...

Page 11: ...fine filter The backwashing valve opens on the bottom side of the device By reversing the water flow from inside to outside deposits on the sieve fabric are carried away and rinsed out with the back wash water The suction pipes also clean the inside of the transparent filter bowl with wiper lips during their movement The degree of contamination and cleaning process can be observed from the outside...

Page 12: ...tton on the handwheel cover for at least 3 seconds The time interval of two months is restarted Attention do not dispose of used batter ies with the household waste but in accor dance with the local waste disposal regula tions 4 1 3 Backwashing WARNING Persons who due to their phys ical sensory or mental abilities or their inexperience or lack of knowledge are unable to operate the device safely m...

Page 13: ...lation 5 Servicing 5 1 Cleaning CAUTION Do not use household cleaning agents to clean the outside of the device but only use clear water to avoid embrittlement of the plastic 5 2 Warranty and maintenance Prerequisite for obtaining the statutory war ranty claim is regular backwashing see chapter 4 1 The DIN EN 13443 1 pre scribes that the backwashing must take place every six months JUDO however re...

Page 14: ...taller or the closest customer service point Filter bowl becomes clouded Hairline cracks on the filter bowl Filter bowl was exposed to high temperatures or solvents Inform the installer or the closest customer ser vice point If water escapes close shut off valves Have the filter bowl replaced immediately The down stream pressure increases slowly at zero flow Inadmissi ble pressure increase due to ...

Page 15: ...ow after backwashing with a pressure loss of 0 2 0 4 bar 4 1 6 7 m h 4 7 7 6 m h 5 3 8 5 m h Mesh size2 sieve insert 0 1 mm 0 1 mm 0 1 mm Water temperature and ambient temperature max 30 C max 30 C max 30 C Threaded connection according to DIN EN 10226 1 Weight 2 6 kg 2 7 kg 3 3 kg Order no 8010072 8010073 8010074 1 Applies to a fully opened backwashing valve and 2 3 bar mains pressure 2 Standard ...

Page 16: ...e pipe middle E Installation depth up to the pipe middle F Waste water connection up to the pipe middle G Waste water nominal diameter G1 Waste water nominal diameter alterna tive 7 2 Accessories Expansion QUICKSET JQR order no 8250041 for series connection of two devices e g filter and water treatment plant PRO SAFE leak protection order no 8140011 Safety block JSB Best Nr 8735260 for retrofittin...

Page 17: ...Technical data 1701582 2018 12 JUDO JPF 17 7 3 Spare parts JPF 1 ...

Page 18: ... alarm 1 3 Battery 1 5 V type AAA set with 2 pcs 1 2060347 8 4 Countersunk screw M5 12 1 5 Disc A 6 4 1 6 Backwash reminder alarm 1 7 Adjusting ring 1 8 Sheet metal screw 3 5 13 4 9 Top of housing JPF 1 2010395 41 9 Top of housing JPF 1 1 2010396 41 9 Top of housing JPF 1 1 2010397 41 10 Cylinder screw M6 40 6 11 Flange ring 1 12 Filter bowl 1 2010424 149 13 O ring 10 3 2 14 Driver 1 2010146 53 15...

Page 19: ...on piece 1 28 Cover 1 29 Filter funnel 1 List of spare parts JPF 1 1 AU Accounting unit items without AU are only available as part of a set Replacement interval 3 years 4 years 8 Disposal Packaging waste is to be sent to the local recycling system To protect environment old appliances must not be disposed of with household waste Instead use the local collection and return points which are committ...

Page 20: ... 61 906 40 59 E mail info judo online ch judo online ch BENELUX JUDO Wasseraufbereitung GmbH Filiaal Filiale BeNeLux Laarbeeklaan Av du Laerbeek 72 A1 B 1090 Brussel Bruxelles Phone 32 0 24 60 12 88 Fax 32 0 24 61 18 85 E mail info benelux judo eu judo eu FR JUDO France SARL 76 Rue de la Plaine des Bouchers Technosud F 67100 Strasbourg Phone 33 0 3 88 65 93 94 Fax 33 0 3 88 65 98 49 E mail info ju...

Reviews: