JUDO i-soft TGA 4
15
Operation
Settings
– Language:
DE, EN, FR, NL, IT
– Desired water hardness (see
chapter 5.4.3 “Setting the desired water
hardness”)
– Correction of the desired water hardness
(see chapter 5.4.5 “Desired water hard-
ness recalibration”)
– Salt top-up quantity, salt reserve
– Leakage alarm on/off (limit values and
sleep mode time only visible if leakage
alarm is activated).
– Water hardness unit:
°dH, °e, °f, gpg, ppm, mmol/l, mval/l
– Lighting, contrast, tone
– Functioning of the fault indication relay
(see chapter 5.9 “Potential-free signal
relay”)
– Factory setting
(see chapter 5.15 “Resetting to factory
setting”)
Operating data
– Total raw water volume since commis-
sioning [m³]
– Total number of regenerations since
commissioning
– Total number of maintenances since
commissioning
Info
Various information is displayed here such
as salt reserves and capacity, device type,
device number, customer service telephone
number, history of the warning messages
and fault indications, software version, hard-
ware version, the date for the next neces-
sary maintenance intervention and the cur-
rent (instantaneous) water flow.
5.4
Start of operation
– To shorten commissioning, fill approxi-
mately 5 litres of water into the salt res-
ervoir
(until just above the intermediate
floor).
– Fill 25 - 50 kg of regenerating salt into
the salt reservoir.
The regenerating salt must as a minimum
comply with the requirements of DIN EN 973
and be of food-grade.
Our recommendation:
Broxo or Solvay
salt, either as blocks, tablets or coarse
grains 7 - 15 mm. If other regenerating salts
are used, then the salt reservoir
must be
cleaned at shorter intervals and the intake
strainer replaced more frequently.
– Remove the cover.
– Enter the date of installation on the label
– Open the water supply (stopcock or
shut-off valve).
– Ensure that the bypass valve (if in-
stalled) is set to “Operate”.
NOTICE
For safety reasons, the water softening sys-
tem must be
immediately
flushed and re-
generated for bleeding
:
See chapters 5.4.1 and 5.4.2 for this pur-
pose!
Fig. 8:
Device and order no. plus
Label “Date of installation”
Device-no.
Order no.
Label
“Date of installation”