JUDO i-soft TGA 4
25
Operation
5.12 Conversions / changes / spare
parts
Only original spare parts may be used!
Unauthorised conversions and changes are
forbidden for safety reasons! Such actions
could impair the functioning of the water sof-
tening system. The imprinted approval
marks are only valid if original spare parts
are used.
5.13 Maintenance/repair
NOTICE
Before performing work on the water sof-
tening system that goes beyond pure oper-
ational use, the water softening system
must be depressurised!
If this is ignored, the result may be uncon-
trolled egress of water resulting in water
damage to the building/home. Therefore the
instructions given in chapter 4 “Installation”
and chapter 7 “Servicing” must be strictly
observed.
5.14 Interruption of operation
The water supply to the water softening sys-
tem is interrupted. The main stopcock is
closed or the bypass valve is switched over.
– When disassembled, the water softening
system must be stored in a dry and frost-
free location.
– The connection flange must be protect-
ed against dirt and damage.
– Once the water softening system is fitted
and started again, it must be flushed and
regenerated (see chapter 5.4 “Start of
operation”).
5.15 Resetting to
factory setting
All customer settings (e.g. desired water
hardness and residual hardness correction)
can be reset to the factory setting in the fol-
lowing way:
Press the
key 1x and then
2x. The
display shows the following:
Press key <OK> 1x and then key
as often
as necessary, until the display indicates the
following:
Press the <OK> key. The display shows the
following:
Press key
or
to change between
<yes> and <no>.
The following default values are recreated
by pressing key <OK> with <yes> selected.
– Desired water hardness 10 °e
– Residual hardness correction = 0 (reset)
– Leakage alarm
•
Leakage alarm activated
•
max. water volume: 300 l
•
max. water flow: 4000 l/h
•
max. drawing time: 30 min
– Fault indication relay: NOC function
– Lighting 80 %, contrast 50 %
Pull the power supply unit out of the
socket! (If present, also pull out the
power supply unit of the downstream
dosing pump!)
Main menu
• Settings
Setting
• Factory setting
Factory setting
<no>