Installation

4.1.2 Installed position

ATTENTION

(see chapter “Safety information and dan-
gers due to non-compliance”)

Always install the Domestic Water in a verti-
cal position (± 5°)!

Failure to observe this can cause uncon-
trolled backwashing water to escape and
can result in damage caused by water.

4.1.3 Mounting the built-in rotary 

flange

Install using the supplied built-in rotary
flange. The built-in rotary flange is used as a
connecting element between the pipe and
the Domestic Water.

It is suitable for both horizontal and vertical
pipes.

The built-in rotary flange must be in-
stalled in the direction of flow. This is
marked by a cast in arrow.

(see Fig. 4)

Failure to comply with this means the Do-
mestic Water cannot work.

ATTENTION

(see chapter “Safety information and dan-
gers due to non-compliance”)

The flange surface of the built-in rotary
flange must be in a vertical position! The
built-in rotary flange must be fitted so that
mechanical stresses cannot occur! Other-
wise mechanical damage can result in the
built-in rotary flange. Otherwise mechanical
damage can result, the pipe may burst or the
built-in rotary flange can break. This can re-
sult in major water damage.

In this case, people close to the Domestic
Water are exposed to a health risk due to
the large quantities of water.

Therefore, during installation, ensure that no
large forces act on the pipe, built-in rotary
flange and Domestic Water.

4.1.4 Mounting the Domestic Water

The built-in rotary flange for the Domestic
Water is supplied with bayonet drill holes.
The necessary seals and screws for this Do-
mestic Water have already been mounted.

Do not unscrew the screws!

Insert the four flange screws in the bay-
onet drill holes on the built-in rotary
flange (see Fig. 3I).

Turn the Domestic Water in a clockwise
direction as far as it will go (see Fig. 3II).

Tighten the four flange screws.

Fig. 3:

Built-in rotary flange with Bayonet Fixture

Select the torque (approx. 4 Nm) so
that the gasket closes and the Do-
mestic Water is not damaged or
strained!

I

II

Summary of Contents for 8170238

Page 1: ...putting the unit into service These must always be issued to the owner user Extended warranty peri od if a service agreement is concluded Installation and Operating Instructions JUDO JUKOMAT LongLife...

Page 2: ...only permitted with special approval Dear Customer Thank you for the confidence you have shown in us by purchasing this unit With this Domestic Water you have purchased a state of the art unit This Do...

Page 3: ...JUDO JUKOMAT LongLife 3...

Page 4: ...d dan gers due to non compliance The instruction manual must be permanent ly available at the place in which the Domes tic Water is used This instruction manual is intended to make it easier to famili...

Page 5: ...ion and dan gers due to non compliance In detail failure to observe the general dan ger symbols can result for example in the following risks Failure of important functions of the Domestic Water Dange...

Page 6: ...f the art standards and the generally accepted safety regula tions in Germany The Domestic Water may only be used as described in the instruction manual Any oth er or further use is deemed not to be i...

Page 7: ...maged by water which escapes from the Domestic Water during backwashing or improper use If the electrical devices equipment are connect ed to the power supply a short circuit can al so occur In this c...

Page 8: ...tions for drinking water installations in ac cordance with DIN 1988 They are tested by the DVGW Deutsche Vereinigung des Gas und Wasserfaches e V technical scientific association for the gas and wate...

Page 9: ...ac cess to the Domestic Water ATTENTION see chapter Safety information and dan gers due to non compliance The ambient temperature must not ex ceed 30 C 86 F At higher tempera tures or direct sun radi...

Page 10: ...rotary flange must be fitted so that mechanical stresses cannot occur Other wise mechanical damage can result in the built in rotary flange Otherwise mechanical damage can result the pipe may burst o...

Page 11: ...e dimensioning depends on the local cir cumstances e g wastewater pipe gradient number of pipe bends length of the waste water pipe etc The dimensioning must at least allow all the wastewater to be di...

Page 12: ...12 JUDO JUKOMAT LongLife Installation 4 2 1 Backwashing water discharge options JUKO LF A 1 JUKO LF A 1 2 Fig 5 Backwashing water discharge options 200 mm 200 mm 80 mm 20 mm 20 mm 20 mm 20 mm...

Page 13: ...shing see chapter Discharging the backwashing water After backwashing and venting the Do mestic Water station is ready for use Check the default time control values set in the factory and adjust if ne...

Page 14: ...able time intervals are written on the side of the control electronics To change the time interval pull off the ca ble lug 2 and push it onto the pin of the new time interval selected Replace the hood...

Page 15: ...stic Water station through the built in rotary flange 1 The automatic controls 3 automatically start the backwashing The handwheel 2 therefore then only has a free discharge function The cleaning proc...

Page 16: ...lange 2 Handwheel for free discharge 3 Automatic controls 4 Filter bell 5 Pressure reducer 6 Manometer 7 Pressure reducer handwheel 8 Pressure reducer cover JUKO LF A 1 JUKO LF A 1 JUKO LF A 1 2 Fig 1...

Page 17: ...ty information and dan gers due to non compliance Unauthorised persons must not operate the Domestic Water station Persons who oper ate the Domestic Water station must ob serve the operating instructi...

Page 18: ...side and pulling off Release the battery from the connection clip of the connection lead behind the electric circuit Replace the battery and insert in the connection clip Insert the power supply unit...

Page 19: ...be re moved from the flange or unscrewed the chapter Intended use must always be ob served Protect the flange surfaces from dam age Damaged flanged surfaces cannot close tight As a result escaping wa...

Page 20: ...socket Fault reoccurs Inform the fitter or nearest customer service centre Dirt in the ceramic flushing valve Water flow rate falls Screen is blocked Red indicator light is lit Fault in the automatic...

Page 21: ...JUDO JUKOMAT LongLife 21 Notes Notes...

Page 22: ...th the legal warranty claim according to DIN 1988 Part 8 it is necessary that the backwashing takes place at least every 2 months after operat ing conditions exist Further an annual check of the set d...

Page 23: ...perating pressure is lower in order to ensure the optimum func tion of the Domestic Water The backwashing volumetric flow given ap plies to 2 3 bar mains pressure and for a completely opened flushing...

Page 24: ...centre D Height below pipe centre E Depth to pipe centre Fig 13 Installed dimensions 1 Montage Built in rotary flange horizontal Montage Built in rotary flange vertical Model A B C D E JUKO LF A 180...

Page 25: ...E 1 or 1 with bayonet fixture and screw connection JUKO LF A 1 2 1 x Built in rotary flange JQE 1 or 2 with bayonet fixture and screw connection 9 7 Accessories 1 JUDO JQR expansion quickset Order no...

Page 26: ...26 JUDO JUKOMAT LongLife Spare Parts 10 Spare Parts 10 1 JUKO LF A 1...

Page 27: ...54 98 13 Manometer seal 1 1200117 3 14 Manometer 0 10 bar 1 1610390 20 15 Hexagon nut M6 4 1633145 1 16 Profile flange seal 2 1200218 5 17 Cylinder screw M6 x 25 coated 4 2010199 2 18 Strainer 1 20703...

Page 28: ...14 45 Power pack 1 2170208 82 46 O ring 6 07 x 1 3 1 1200137 2 47 Tube connection pre mounted 1 2170222 16 48 Union nut 1 1440151 14 49 Handweel 1 1120461 36 1 VE Unit of Billing Replacement interval...

Page 29: ...JUDO JUKOMAT LongLife 29 Spare Parts 10 2 JUKO LF A 1 2...

Page 30: ...14 Backflow preventer JUKO LF A 1 1 1610318 44 14 Backflow preventer JUKO LF A 2 1 1610454 51 15 O ring 11 x 2 1 1200297 2 16 Complete Plug pre mounted 1 2170184 8 17 Pre fitted RV sleeve JUKO LF A 1...

Page 31: ...3 1 44 Gearing cover 1 1120551 14 45 Power pack 1 2170208 82 46 O ring 6 07 x 1 3 1 1200137 2 47 Pre fitted hose connector 1 2170222 16 48 Union nut 1 1440151 14 49 Handweel 1 1120461 36 1 VE Unit of...

Page 32: ...18 85 e mail info judo online be www judo online be JUDO Austria Zur Schleuse 5 A 2000 Stockerau Tel 43 0 2266 6 40 78 Fax 43 0 2266 6 40 79 e mail info judo online at www judo online at Installed by...

Reviews: