1.  Obtain the raw distance measurement from the sensor. (make sure DIP Switch 3 is ON) 
2.  Get the external temperature measurement. 
3.  Calculate the Correction Factor.  CF = ((Temp C. + 273)/273)^.5 
4.  Multiply the raw distance by the CF. 
 

DIP Switch 4 

600 milliseconds after  power up the air temperature measurement will be output, and stay on the output 
for at least 200 milliseconds before the output changes over to the distance measurement. Some 
dataloggers and control systems do not have the ability to make millisecond resolution delays. When DIP 
Switch 4 is turned on, the air temperature measurement is held on the output for an addition second for a 
total of 1.2 seconds. 
This enables dataloggers and control systems with at least one second delay resolution to obtain the air 
temperature measurement. 
 
Normal sensor timing sequence with DIP switch 4 OFF: 

0 to 400 ms  

 

sensor warm up

 

400 to 800 ms    

air temp. output

 

600 to 2600 ms    

error checking

 

2600 ms -  

 

distance output 

Sensor timing sequence with DIP switch 4 ON: 

0 to 600 ms  

 

sensor warm up

 

600 to 1800 ms    

air temp. output

 

1800 to 3600 ms  

error checking

 

3600 ms -  

 

distance output 

MISC. 

Some control systems and dataloggers want to know minimum and maximum range values instead of scale 
multipliers. These values do not denote the actual maximum range of the sensors. 

Distance: 
Scale 

Minimum 

Maximum 

Inches 

492.15 

Centimeters 

1250 

Air Temperature: 
Scale 

Minimum 

Maximum 

Degrees Kelvin 

500 

WARRANTY  

The Judd Communications Depth Sensor is warranted by Judd Communications to be free of defects in 
material and workmanship under normal use and service for a period of one year from the date of 
shipment. Judd Communications obligation under this warranty is limited to repairing or replacing 
defective products. The customer shall assume all costs of removing, reinstalling, and shipping defective 
products to Judd Communications. This warranty shall not apply to any Judd Communications products 
which have been subjected to modification, misuse, neglect, accidents of nature, or shipping damage. This 
warranty is in lieu of all other warranties, expressed or implied, including warranties of merchantability or 
fitness for a particular purpose. Judd Communications is not liable for special, indirect, incidental, or 
consequential damages. 
 
Products may not be returned without prior authorization. To obtain a Return Materials Authorization, 
contact Judd Communications. Phone (801)424-2889 
 
Non-warranty products returned for repair should be accompanied by a purchase order to cover the repair. 

Summary of Contents for Depth Sensor

Page 1: ...measuring snow depth or water levels The sensor measures the distance from the sensor to a target The sensor works by measuring the time required for an ultrasonic pulse to travel to and from a target surface An integrated temperature probe with solar radiation shield provides an air temperature measurement for properly compensating the distance measured An embedded microcontroller calculates a te...

Page 2: ... 2 5 Volt Range 0 5 Volt Range Degrees Kelvin 200 degrees Volt 100 degrees Volt The JC Depth Sensor performs multiple echo processing Multiple echo processing dramatically improves the reliability of measurements For each measurement cycle two initial measurements are made If the difference between the two distances is less than 1 centimeter then the second sample is saved and output If the differ...

Page 3: ...igh Brown Output Low Differential input Low When single ended inputs are used the Brown lead is not used SENSOR PROGRAMMING The following steps show how to make temperature and depth measurements with the JC Depth Sensor 1 Turn on the sensor by applying a 5 to 12 Volt control signal to the green lead 2 Wait for 800 milliseconds for the depth sensor to warm up and output a temperature measurement 3...

Page 4: ...nterval 01 P End Table 2 Subroutines 3 Table 3 Subroutines Assign the depth sensor subroutine a number note that this number and the calling number need to be the same 01 P85 Beginning of Subroutine 01 1 Subroutine Number Turn ON the depth sensor 02 P86 Do 01 41 Set high Port 1 Wait 0 8 seconds for the sensor to output the Air Temp 03 P22 Excitation with Delay 01 1 EX Chan 02 80 Delay w EX units 0...

Page 5: ...be mounted at least half the distance of the beam diameter or 1 95 meters away from the mast Be careful to avoid obstructed beam paths To determine the minimum distance the sensor must be mounted away from the mast use this formula Crossarm length 194 x Height Depth Sensor Beam Width Examples Perpendicular to Surface The JC Depth Sensor must be mounted perpendicular to the target surface Mounting ...

Page 6: ...should be mounted 4 6 feet away from any vertical supporting structure A good rule of thumb is 2 feet out for every 10 feet the sensor is mounted above the surface The mounting should be adjusted so that the transducer is held parallel to the snow surface Secure the pipe to the supporting tower by using U bolts or tower clamps Measure the distance from the transducer to the target Write this value...

Page 7: ...Solar Radiation Shield on the bottom of the sensor is made of white PVC plastic and will yellow after several years of exposure to ultraviolet light The shield is easily removed by gently twisting it counter clockwise to unscrew it Replacement fittings can be obtained from any plumbing supply store or ordered from Judd Communications Check the shield periodically for discoloration and to make sure...

Page 8: ...Mode Normally when using Free Run Mode the Green Sensor Enable wire would be connected to with the Red wire to 12 Volts so the sensor is enabled continuously The measurements are made using the error check retry algorithm so the output is updated every 1 5 to 3 5 seconds Free Run Mode is used with systems that need continuous operation It is also useful when the sensor is used with a datalogger or...

Page 9: ...ystems and dataloggers want to know minimum and maximum range values instead of scale multipliers These values do not denote the actual maximum range of the sensors Distance Scale Minimum Maximum Inches 0 492 15 Centimeters 0 1250 Air Temperature Scale Minimum Maximum Degrees Kelvin 0 500 WARRANTY The Judd Communications Depth Sensor is warranted by Judd Communications to be free of defects in mat...

Reviews: