background image

©JRI  

 

KEEP THE BATERY FAR FROM THE FIRE ; DO NOT TRY TO RELOAD OR TO SHORT CIRCUIT IT. USE ONLY BATTERIES 
SUPPLIED BY JRI (REF 10102) 

V.

 

FEATURES 

FEATURES 

Mini SPYRF GREEN 

Measurement range  

-40 +85°C 

Number of channels 

1 internal or external probe 

Remote sensor 

Ø4 x50mm / 0,5m Cable 

Type of input 

PTC 

Accuracy 

±0,4°C from -20 à +30°C  
±0,5°C from -40 to -20°C & +30 to +80°C 
±0.7°C above +80°C 

Recording interval 

1sec to 90 min 

Memory size 

10 000 measur1ko 

Operating conditions 

-30 +70°C 

Temperature for storage 

-40 + 85°C 

Radio range (in free field) 

Max 58 m adjustable 

Radio band  

868MHz or 902MHz 

Battery lifetime 

2 years 

Dimensions 

85x55x18mm 

Protection level  

IP67 

EN 12 830 compliance 

Yes : this device must be regularly checked according to 
EN 13 486 (1 time per year recommended) 

CE ERM compliance 

EN 301 489 / EN 61000 / EN 61010 
EN 55022 / EN 300 220 

 

VI.

 

REPLACING BATTERY 

When the Mini SPY RF Green battery has to be replaced, a technical alarm is processed by the software Sirius 
 

 
 

 
 
To replace the battery, follow the instructions below :  
 
 

 

 
 
 
 
 
 

 
 

 
 
 
 
 
 
 
Restart the device by pressing 5’’ on the pushbutton after changing the battery. 

DOWNLOAD THE SPY RF MEMORY BEFORE CHANGING THE BATTERY. DO NOT WAIT 
UNTIL THE BATTERY IS EMPTY OTHERWISE THE MEMORY WILL BE DELETED 

Open the MiniSpy 
RF Green 

Replace the battery 

Short circuit the two pins 
with a paper clip to reset 
the device  

Replace the seal and 
close the device 

Summary of Contents for Mini SPYRF Green

Page 1: ...USER MANUAL Mini SPYRF Green 10101 C...

Page 2: ...a Stop 5 b Start 5 c Waiting mode 5 d Measurement start 5 e Automatic start 5 f Manual start 6 g Alarm visualisation 6 h Measurement stop 6 i Auto control or top zone 6 j Leds and pushbutton actions...

Page 3: ...row away the device CE MARKING this equipment is certified to comply with the European regulation for the electric security inflammability disturbing radiation emission and immunity to surrounding ele...

Page 4: ...iture or close to the antena Obstacles thickness in the way of the waves The absorption is more important in diagonal as perpendicularly Waves cannot pass through full metallic walls On the other hand...

Page 5: ...e on 2 if you press 5 on the push button In this case the Mini SPY RF GREEN is waiting for programming Configuration Mini SPY RF GREEN configuration is done from the Sirius software and then transferr...

Page 6: ...dby mode with Sirius when you do not use your recorder With the pushbutton this option is valid only if the Mini SPY RF GREEN is configured in transport mode with a start by pushbutton i Auto control...

Page 7: ...d 2 beginning of measurements Delayed date time Immediatly Measure Green led 10 auto control Device set up in transportation mode Pushbutton pressing Mode 5 5 appui 10 Off The 2 leds are on and flash...

Page 8: ...ttery lifetime 2 years Dimensions 85x55x18mm Protection level IP67 EN 12 830 compliance Yes this device must be regularly checked according to EN 13 486 1 time per year recommended CE ERM compliance E...

Page 9: ...JRI 9 VII COMPLIANCE TO THE EN 12830 VIII WARRANTY...

Page 10: ...We bring you a global solution which makes your maintenance easier This overall service offer includes maintenance and also metrological services which ensure you that your system is fully performant...

Reviews: