5-46
When the [LOAD] in the small screen is selected in the Regional Channel Setting Menu, the
preservation list of manual inputs is displayed.
Moreover, the contents of the setting selected from preservation lists can be registered.
Transponder saves a maximum of nine channel management information.
The data applicable to the condition is eliminated when the ship is separated more than 500NM
from the set-up area or when five weeks pass from the saved time.
This is for saving the time to input the same data manually every time.
A maximum of 8 affairs from the newest manual input settings can be reconfirmed and
re-registered.
The screen
①
is displayed if the [LOAD] is selected after the cursor is moved into small screen of
the Regional Channel Setting Menu.
Move the cursor onto
1.
at
①
. “NO DATA” is displayed if there is no data and then the cursor is on
[EXIT] in the small window.
[CHECK], [SAVE], etc. cannot be selected.
REGIONAL CH.SET UTC11:44
BRG : RNG
NAME / MMSI
270°: 0.18NM
35°: 0.29NM
* 22°: 0.92NM
OCEAN-LINE
QUEEN
ABCDEFG-MARU
1.
CH A : 1087 NARROW
CH B : 2084 NARROW
TX/RX MODE: TX/RX,TX/RX
(CH A,CH B)
TX POWER : LOW
ZONE SIZE : 4NM
AREA (NE) :N 15°22.33
’
E 145°59.99
’
AREA (SW) :N 14°22.33
’
E 143°59.99
’
[EXIT] [CHECK] [SAVE]
[ERASE]
REGIONAL CH.SET UTC11:44
BRG : RNG
NAME / MMSI
270°: 0.18NM
35°: 0.29NM
* 22°: 0.92NM
OCEAN-LINE
QUEEN
ABCDEFG-MARU
▲
1.
CH A : 1022 NARROW
CH B : 2022 NARROW
E 145°59.99
’
7.AREA (SW) : N 35°02.33
’
E 145°39.99
’
▼
[EXIT] [CHECK] [SAVE]
[ERASE]
REGIONAL CH.SET UTC11:44
BRG : RNG
NAME / MMSI
270°: 0.18NM
35°: 0.29NM
* 22°: 0.92NM
OCEAN-LINE
QUEEN
ABCDEFG-MARU
▲
4.CH A : 1022 NARROW
CH B : 2022 NARROW
E 145°59.99
’
AREA (SW) : N 35°02.33
’
E 145°39.99
’
▼
[EXIT]
[CHECK] [SAVE]
[ERASE]
[EXIT]
[CHECK]
[SAVE]
[ERASE]
NG AREA 500NM OVER
[EXIT] [CHECK]
[SAVE]
[ERASE]
OK
Select the re-registered
data.
Press the CLR key to
go back to the
CHANNEL
SETTING PAGE
Transponder answers it as NG.
Transponder answers it as OK and
then [SAVE] can work.
Cursor is returned to the state of
②
by [EXIT] selection.
Select [CHECK]
1
The cursor moves onto
[EXIT] after
selecting the data.
3
4
2
Summary of Contents for JHS-182 -
Page 1: ...Automatic Identification System JHS 182 Instruction Manual 7ZPJD0226 ...
Page 6: ...v External Views NTE 182 AIS Transponder NCM 779 AIS Controller ...
Page 7: ...vi NQE 3182 Connection Box ...
Page 8: ...vii NBD 577B Power Supply Unit NQD 4382 Junction Box ...
Page 13: ...1 3 1 3 3 Configuration System Block Diagram ...
Page 14: ...1 4 1 4 Outline Outline Drawing of NTE 182 AIS Transponder Unit mm Mass approx 2 6 kg ...
Page 15: ...1 5 Outline Drawing of NCM 779 AIS Controller Unit mm Mass approx 1 0 kg ...
Page 16: ...1 6 Outline Drawing of NQE 3182 Connection Box Unit mm Mass approx 2 5 kg ...
Page 17: ...1 7 Outline Drawing of NBD 577B Power Supply Unit Unit mm Mass approx 3 8 kg ...