5-48
5.3.4.4 LONG RANGE RESPONSE SETTINGS
To set the Long Range Response, select
4.LONG RANGE RESPONSE
.
Auto response (AUTO) and manual response (MANUAL) can be selected.
This setting works when a long range communication device is connected.
The default setting is AUTO. Use the Jog Dial for selection and confirmation.
Long Range Response Screen
5.3.4.5 BUZZER SETTINGS
To set the buzzer beeping functions, select
5.BUZZER
.
Each buzzer functions can be set enable (ON) or disable (OFF) as followings..
BUZZER : ON / OFF
ON : Key touch beeping is enable and the other buzzer function can be work by the each setting.
OFF : All buzzer functions are disable including key touch beeping.
MESSAGE : ON / OFF
When a binary message is received.
GUARD ZONE ALARM : ON / OFF
When a other ship approaches within the guard zone range
LOST TERGET ALARM : ON / OFF
When a other ship information within the range is not received for 6 minutes.
ALARM : ON / OFF
When a failure alarm occurs.
Setting of Buzzer functions
3.
LONG RANGE RESPONSE
:
AUTO
5.BUZZER :
ON
- MESSAGE :ON
- GUARD ZONE ALM :OFF
- LOST TARGET ALM:OFF
- ALARM :ON
Summary of Contents for JHS-182 -
Page 1: ...Automatic Identification System JHS 182 Instruction Manual 7ZPJD0226 ...
Page 6: ...v External Views NTE 182 AIS Transponder NCM 779 AIS Controller ...
Page 7: ...vi NQE 3182 Connection Box ...
Page 8: ...vii NBD 577B Power Supply Unit NQD 4382 Junction Box ...
Page 13: ...1 3 1 3 3 Configuration System Block Diagram ...
Page 14: ...1 4 1 4 Outline Outline Drawing of NTE 182 AIS Transponder Unit mm Mass approx 2 6 kg ...
Page 15: ...1 5 Outline Drawing of NCM 779 AIS Controller Unit mm Mass approx 1 0 kg ...
Page 16: ...1 6 Outline Drawing of NQE 3182 Connection Box Unit mm Mass approx 2 5 kg ...
Page 17: ...1 7 Outline Drawing of NBD 577B Power Supply Unit Unit mm Mass approx 3 8 kg ...