4. Operation
4-32
4.12 Alert Control
Over view
This section describes the types, displays, and settings of each alert.
JFE-400/700 Echo Sounder displays alerts in accordance with IEC62923 Ed.1.0.
Alert priority is defined as three types according to its priority and severity as shown in the table below.
Priority Description
Display
Color Sound
Display
Status
Alarm
An alert indicating a state asking sailors to pay immediate
attention and take immediate action.
Red Present
(repetitive)
Before acknowledgement: Blinking
After acknowledgement: Lighting
Warning
An alert indicating that the state has changed, which although
not immediately dangerous, but may become so in the near
future if no action is taken. Warnings are alerts displayed for
preventing possible future hazardous states.
Orange Present
(Once)
Before acknowledgement: Blinking
After acknowledgement: Lighting
Caution
Although these are neither alarms nor warnings, these alerts
indicate that it is necessary to pay more than normal attention
to cautions, statuses, or to the supplied information.
Yellow
No Sound
Only Lighting
In addition, each alert is categorized as follows according to IEC62923-1:
Category A: alert for which graphical information at the task station directly assigned to the function generating
the alert is necessary, as decision support for the evaluation of the alert related condition
Category B: alert where no additional information for decision support is necessary besides the information
which can be presented at the CAM(central alert management) system.
List of generating alert
The following alerts are generated on JFE-400/700 Echo Sounder
No. Name
Detail
information
on screen
Alert
ID
Alert
instance
Priority Category
Responsibility
Transfer
Escalation Backup
Navigator
Call
1
DEPTH ALERT
FWD depth, take grounding
avoidance
3031 1
Alarm A
No
N/A
Yes
2
DEPTH ALERT
AFT depth, take grounding
avoidance
3031 2
Alarm A
No
N/A
Yes
3 LOST
DEPTH
FWD
lost
bottom,
check chart
10352 1
Warning B
Yes
warning
to
warning
No
4 LOST
DEPTH
AFT
lost
bottom,
check chart
10352 2
Warning B
Yes
warning
to
warning
No
5
NO PAPER
No paper of printer
10356 -
Caution B
N/A
N/A
No
6 LOST
PRINTER
Discommunication
with printer
10359 -
Caution B
N/A
N/A
No
7 WEAK
ECHO
TX/F FWD
transmission
level down
10363 1
Caution B
N/A
N/A
No
8 WEAK
ECHO
TX/A
AFT
transmission
level down
10363 2
Caution B
N/A
N/A
No
9
WEAK ECHO RX/F
FWD receive
sensitivity down
10365 1
Caution B
N/A
N/A
No
10
WEAK ECHO RX/A
AFT receive
sensitivity down
10365 2
Caution B
N/A
N/A
No
11
LOST PROCESSOR
Processor com fail,
check LAN cable
10353 -
Warning
B Yes warning
to
warning
No
12
LOG MEMORY FAIL
Cannot log Depth
10362 -
Caution B
N/A
N/A
No
*The Transducer alerts related to FWD and AFT are generated depending on the installation position and
number of installations about Transducer.
*
Backup Navigator Call function are available when connected to the BNWAS
(Bridge Navigational Alarm
System).
Summary of Contents for JFE-400
Page 1: ...Echo Sounder INSTRUCTION MANUAL ...
Page 2: ......
Page 19: ...Explanation of Terms xvii Blank Page ...
Page 34: ...2 Control Panel 2 2 Blank Page ...
Page 38: ...3 Display 3 4 Blank Page ...
Page 58: ...4 Operation 4 20 2 HISTORY print mode 3 LOG print mode Depth data and graph ...
Page 80: ...6 Consider Installation 6 6 2 Blank Page ...
Page 84: ...8 Disposal 8 2 Blank Page ...
Page 86: ...9 Specification 9 2 Blank Page ...
Page 102: ...10 Appendix 10 16 Blank Page ...
Page 103: ......