5. Maintenance & Check
5-4
5.6 Replacing Fuses
Exchange the fuse for the one of our specification. Exchange it after confirming the cause to which the fuse
is blown. Moreover, turn off the main switch of the power supply CQD-2348 when you exchange fuses
(Press
○
sign side).
No. Model
type
Rating
Remarks
FH1
FGBO-A 250V 2A
250V 2A
For power supply in this
equipment
FH2
MF51NR 250V 0.5 or equivalent
250V 0.5A
For power supply alert
circuit in this equipment
5.7 Repair Parts
Parts name
Type
Code
Remarks
Main
Unit
CDJ-2594 CDJ2594
TX/RX Unit
CMN-869-20 CMN869-20 200kHz
standard
CMN-869-50 CMN869-50 50kHz
standard
CMN-869-22 CMN869-22 200kHz/200kHz
as
option
CMN-869-25 CMN869-25 200kHz/50kHz
as
option
CMN-869-55 CMN869-55 50kHz/50kHz
as
option
Power Supply Unit
CBD-2016 CBD2016
I/F Unit
CQD-2348 CQD2348
LCD panel kit
CCN-1650 CCN1650 For NWZ-1650 Display unit
Control board
CMJ-612 CMJ612
5.8 Regular replacement parts
Parts name
Type
Code
Replacement time
Remarks
LCD panel kit
CCN-1650
CCN1650
About 40,000hours
About 5 years in continuous
use as the guideline
Summary of Contents for JFE-400
Page 1: ...Echo Sounder INSTRUCTION MANUAL ...
Page 2: ......
Page 19: ...Explanation of Terms xvii Blank Page ...
Page 34: ...2 Control Panel 2 2 Blank Page ...
Page 38: ...3 Display 3 4 Blank Page ...
Page 58: ...4 Operation 4 20 2 HISTORY print mode 3 LOG print mode Depth data and graph ...
Page 80: ...6 Consider Installation 6 6 2 Blank Page ...
Page 84: ...8 Disposal 8 2 Blank Page ...
Page 86: ...9 Specification 9 2 Blank Page ...
Page 102: ...10 Appendix 10 16 Blank Page ...
Page 103: ......