Centrum KD2
- 4 -
Centrum KD2 VR
User code:
199
6
195
9
200
0
Ambush code: 199
7
195
0
200
1
MAID CODE
The maid code is the code of user nº 5.
This code is able to disarm only once every arming, as well
as the Master code has enabled it through the “Maid
Code” function.
If the code has just disarmed or the function is not
enabled, if it is wanted to disarm, the control panel will not
allow. The keypad will display the cause “can not disarm
as it’s service code”
This code can always arm.
SYSTEM IN ALARM
The system will turn in alarm when:
The control panel is armed and detects an instant zone.
If the control panel is in entry/exit path and detects any
zone that is not entry/exit.
If the control panel has not been disarmed, with the entry
time concluded.
A detection on a 24 Hours / Tamper zone will always turn
the control panel on alarm.
When an alarm takes place in the control panel, the
outputs will activate, the keypad buzzer will sound and the
keypad will show the zone that has caused the alarm.
Everything remains active during the programmed time to
the output.
Concluded the alarm, the Alarm Memory Led will light and
can happen:
The zone that has produced the alarm stops detecting.
This zone is restored and if it detects again, will activate the
alarm.
If the zone that has produced the alarm continues
detecting, will bypass (according to programming) and it
will not activate the alarm again until resetting.
If the zone continue detecting and has programmed
“Automatic reset” order, won’t activate the alarm again
until conclude Anti-Larsen time.
If some user disarms the control panel during the alarm;
the output/s, the buzzer sound and the keypad alarm
indication will disable.
If a fire zone activates during the alarm, this zone will have
priority on the rest of zones.
TAMPER / 24 HOURS ZONES
These zones will always activate the alarm despite the
state of the area that holds them, when in alarm if they
are disarmed and continue detecting will be bypassed,
stopping the alarm
AVERY IN ZONE
The failure detection in a zone is indicated through the
keypad, the memory led blinks until the Failure disappears.
Besides the led, the alarm control panel can send a
phone report to the central receiver. This function of failure
can be converted to Tamper by programming the
option ( considers failure as tamper).
AMBUSH ALARM (HOLD-UP ZONE)
If a zone, that is ambush programmed, detects, the
control panel will activate the output that has assigned,
and the phone communicator send the ambush report.
The keypad not show anything and the buzzer will not
sound.
FIRE ALARM
If there is a fire zone and it detects, the pre-alarm time will
begin and if during this time the zone stop detecting, will
return to initial conditions. Concluded the time, if the zone
keeps detecting, will activate the alarm.
If the reset function [Key 9] occurs during the pre-alarm,
will stop the pre-alarm and the zone that is detecting, will
get bypassed.
The fire alarm will finish when the outputs stop.
It will also finish when entering a user code or through the
key, if the zone continues detecting, it wills self bypassed.
The fire alarm can also activate by pressing at the same
time and during 2 seconds:
F2 +
4
The activation is direct. There is no fire pre-alarm time. If
during this activation there is some fire zone on detection,
will send the alarm report of this zone.
PHONE COMMUNICATOR
The Control Panel has a built-in Phone communicator that
can send the occurred events:
To Receiver Station
To private telephones
RECEIVER STATION
When an event takes place in the control panel, if this
event has assigned a phone report, the control panel will
call to the receiver station indicating the happened event.
The control panel sends to the central receiver:
The account code
The report
The number of the zone, user...
The control panel can send periodically the Test event to
Central Receiver for supervision of telephone line with
control panel. The time is programmable and variable
from 1 to 255 hours.
PRIVATE TELEPHONES
When an alarm takes place in those zones that have
assigned
“Zones that communicate tone alert”
, will call
to the programmed private telephones reproducing a
tone alert.
The communication working mode is programmable:
−
Calls once
−
Calls to all the telephones
−
Security redial
* If the control panel gets disarmed while the dialer is
calling, the disarming will stop the call
* When picking up the call, the dialer will play over and
over the tones, between 8 repetitions will do a pause of 4
seconds in order the user to be able to do the “call
confirm” (*+9), this way the dialer will stop calling again.
* Once *+9 has been typed, the message playing will
stop
DOWNLOADING
The downloading is the communication that control panel
establishes with the Computer.
Two communication working modes:
Local: by wire
Remote: by telephone
REMOTE CONTROL FUNCTION
The Remote Control is the system that allows the user to
manage the control panel through a Touch tone phone.
Summary of Contents for centrum KD2
Page 1: ...User s Guide Ver 5 12 7...