Centrum KD2
- 14 -
Centrum KD2 VR
If the arming / disarming function is not allowed, the
display will show the reason as:
Cannot Disarm
Maid Code
The Service code can’t
disarm because has
exhausted its function
Cannot Arm
Detect Priority
The panel can’t arm
because is detecting a
priority zone.
Cannot Arm
Level Keyswitch
Can’t arm/disarm by code
because the key switch is
latching
Keypad
Blocked
Panel is locked by 4 wrong
codes
ENTRY / EXIT PATH
During entry or exit paht, the keypad will show the next
screen showing the time lapse.:
T.Path 00:45
[Status of the panel]
PANEL IN ALARM
When there is an alarm in the control panel, the display will
show an alarm message and the name of the zone that
has produced the alarm.
Zones in Alarm
[Alias of Zone]
The keypad will show it until the alarm stop (programmed
time to the output “OUT”).
If several zones have provoked the alarm, the keypad will
show them in a cyclic mode.
Once the alarm has finished the LCD will show the standby
state and then the Alarm memory Led will remain on.
KEYS FUNCTIONS
When pressing a key during
2 sec.
, will carry out the
corresponding function:
1
Zones in Detection
, the keypad shows the
zones that are detecting in that moment. Press
any key to exit this function.
If ‘*’ is pressed before, the keypad will show the
zones in failure.
2
Bypass zones
, the keypad shows the
bypassed zones. Press any key to exit this
function.
3
Event Log
, the keypad shows the last 125
produced events, beginning with the most
recent.
If no code is typed before pressing ‘3’, the
keypad will show ‘
a
’ and the zones that have
caused alarm during the last arming period.
The display shows the Event, the Alias, the Hour
and Date.
DD/MM CID: R 130
HH:MM [Zone / User Alias]
Use these keys to change between events.
-
[F1]:
Shows most recent events
-
[F2]:
Shows past events
-
[
∗
]:
Exits alarm memory function
Hour and Date will appear sequentially in the
LCD
4
Output tests
, activates the outputs of the
control panel during 2 sec.
If ‘*’ is pressed before, the keypad will show the
outputs in failure.
5
Chime Zone
, activates / disables the function
Chime (Buzzer) of the entry/exit zones and the
day zones
7
Reset Alarm Memory
.
Turn off the led
“Alarm memory”. Not deleting the events
8
Tactile sound
, activates / disables the
keypad tactile sound.
9
Reset
, when pressing this key disables
-
The buzzer if it’s sounding
-
The walking test
-
The fire pre-alarm fire
-
Wireless zone low battery sound.
F1 +
1
Police,
sends the police report to the
Receiver Station.
F2 +
4
Fire
, sends the firemen report to
Receiver Station and the display shows
the message of the function
F3 +
7
Ambulance
, sends the report of
medical assistance to the Receiver
Station and the display shows the
message.
F1 +
2
Walking TEST
. Check the control
panel. During 4 min. verifies the state
of the zones. The display shows the
zones that have detected.
F1 +
3
Identifier
. Change the identifier
(upper line of LCD). The 1 by the 2 or
vice versa
F4 +
0
Backlight
. Activates / Deactivates
the LCD backlight
-
On:
The Display always has backlight
on.
-
Off:
Backlight will be active during
20 seconds after pressing a key.
Summary of Contents for centrum KD2
Page 1: ...User s Guide Ver 5 12 7...