background image

 

 

Centrum  KD2 

- 3 -

 

 

Centrum  KD2 VR 

GENERAL FUNCTIONING 

SYSTEM IN STAND-BY 

The initial state of the alarm control panel is disarmed or in 
stand-by. This state is showed through the keypad.  
If there is not and has been not any incidence, the 

keypad leds are off.  
If there is some led lighting or blinking, act according to 
this led: 

 

Status Led. This led shows if control panel is armed 

or disarmed. 

 

 

Led of zones bypass and deprogrammed clock ( 
priority information ) 

 

 

Power Led. This led shows the battery and mains 

state. 

 

 

Alarm Memory Led, shows a possible alarm in the 

system. Blinks if there is avery on the  zones. 

AREAS 

The control panel has up to 2 areas (depending on 

programming), the zones and the codes can be assigned 
freely to any of the areas. 
The working mode of the areas is 

INDEPENDENT

 as the 

arming/disarming of one of the areas won’t affect the 
other. 

A1

A2

 

Zones can be shared between the two areas, then this 
zone will be armed only when the two areas are armed. 

 

The entry/exit path can be shared between the two 

areas, then this path will be active when the two areas 
are armed. 

Also you can assign two independent entry/exit path to 

each areas, having different entry time (Entry time 1 and 
entry time 2), but the will have to  share the same exit 
time.

 

ARMING OF SYSTEM 

We can arm the control panel through: 
User codes. 
Quick-arming function. 
Key switching. 
Wireless keyfobs. 
When the system is armed, the keypad display will indicate 
the action “Arming”, the Led of “control panel state” will 
blink and the buzzer will sound, indicating that it has begun 

the exit time. During this time, the entry/exit zones 
detection’s will not activate the alarm, but if detection 
takes place in the rest of the zones, the alarm will activate.  
Once concluded the exit time, any zone detection will 

activate the alarm.  
When the system is armed, the Led  of “control panel 
state” remains lit. 

QUICK ARMING. 

To arm the system in quick mode without a code, pulse 
the keys at the same time during 2 seconds: 

* + 

This function will 

arm the user code number 8

 arming , 

arming its assigned areas. 

NIGHT BYPASS. 

This is carry out using the

 “Night arming”

, and will arm the 

areas of the user that carries out the function and will 
bypass the zones programmed with the “Night Arming 

bypass” feature. 
This is done by: 

User 

code 

+ F1  + E 

  


sec 

 

 

All this will be displayed through the keypad.  

ARMING WITH PRIORITY ZONES 

If when arming the control panel, it don’t allows the 
arming, and the keypad shows the reason “ It can’t arm 
because there is a detection in a priority zone”, the alarm 
control panel displays that there is detecting some priority 
zone. And until it is not restored (stops detecting), The 

arming is disabled.  
The keypad, after showing the reason, displays the number 
of the zone that is detecting.  
The keypad can bypass these zones (user functions) if 
programming allows. 

SELF-BYPASSING ZONES 

When a zone is programmed as a self-bypassing zone, 
then, when arming control panel, if the zone is detecting, 
the bypass Led will light and the zone will be bypassed. 
This zone will not activate alarm until it is restored and it 
occurs a new detection. 

SYSTEM DISARMING 

The control panel could be disarmed using the user 
codes, the key switch or wireless keyfob...  
When entering in the installation, the entry/exit zone 
detects, the keypad Led of “control panel state” blinks and 
the buzzer sounds indicating that it has begun the entry 
time. Concluded the time, if the system hasn’t disarmed, 

the alarm will activate.  
During the entry time, only the entry/exit and follow zones 
detection is allowed. The detection of other zone/s will 
activate the alarm.  
When disarming the control panel, the keypad will indicate 
the action “Disarming” and the Led of ”control panel state” 
will turn off (programmable option). 
The disarming through the keypad allows up to 4 trials, 
being cancelled during 30 seconds when entering a 
wrong code for fifth time.  
Once the control panel is disarmed, if there are bypassed 
zone/s they  will be restored.  

AMBUSH CODE 

Also called Hold-up or attack code. 
If the user is forced to disarm against his will and wants to 
advice somebody this circumstance, must type the 

ambush code  
When typing the code, the control panel disarms and the 
communicator sends a report with the hold-up event to 
the Central Receiver. The keypad won’t show anything. 
The ambush code is the user code plus 1 at last digit. 
Examples: 

Summary of Contents for centrum KD2

Page 1: ...User s Guide Ver 5 12 7...

Page 2: ...duct and for trusting in our company This product fulfils all the security regulations it has overcome rigorous tests in process production and it is designed to offer you and your client the personal...

Page 3: ...rry out using the Night arming and will arm the areas of the user that carries out the function and will bypass the zones programmed with the Night Arming bypass feature This is done by User code F1 E...

Page 4: ...d detects the control panel will activate the output that has assigned and the phone communicator send the ambush report The keypad not show anything and the buzzer will not sound FIRE ALARM If there...

Page 5: ...ce carried out the On and Off tones will be played indicating the state of the areas of the user code Activate Deactivate Outputs Press and then Output number the panel will reproduce the current stat...

Page 6: ...t and will keep lit until restoring the zone stop detecting ARMING DISARMING In order to arm disarm de control panel introduce a valid user code and then press E User code E Changes panel state In cas...

Page 7: ...ound F1 1 Police sends the police report to the central receiver F2 4 Fire sends the firemen report to the central receiver F3 7 Ambulance sends the medical assistance report to the central receiver F...

Page 8: ...isplay will show If it s desired to store the programmed data press F1 If it s desired to modify the data enter the new data and press E USER CODES PROGRAMMING User code 1 001 1 1 1 1 User code 2 002...

Page 9: ...deleted by programming entry exit path and more through direct functions from the keypad chime and day zone low bat of wireless detector PANEL IN STAND BY With PANEL disarmed the Display shows the sta...

Page 10: ...eans that there are no more events to show Example Alarm in zone 9 25 of August at 12 45 0 9 1 2 4 5 2 5 0 8 4 Output Test activates the PANEL outputs during 2 seconds If is pressed before the keypad...

Page 11: ...Master code from factory is 1111 After that the display will show It s not possible to access to user programming if PANEL is in Alarm Exit programming To exit programming press sequentially E The pa...

Page 12: ...hange the telephone numbers for private call in case you change your mobile private number or telephone Company Private phone n 1 Example Tel 1 123456789 with dial tone detection 200 D 1 2 3 4 5 6 7 8...

Page 13: ...BY When the panel is in standby the display shows the disarmed areas if any area is armed it won t be shown Each 8 seconds the keypad will show a sinoptic of the system State as Status Ta 14 0 C V 14...

Page 14: ...5 produced events beginning with the most recent If no code is typed before pressing 3 the keypad will show a and the zones that have caused alarm during the last arming period The display shows the E...

Page 15: ...vated To modify or remain the state press the suitable key F22S E Changes the State F1 Remain in same state Enabling disarming of the Maid code Press the code and press the function key User Code F32S...

Page 16: ...5 PRIVATE PHONES PROGRAMMING In theses addresses you can change the telephone numbers for private call Private phone Ex Tel 1 1234567 with dial tone detection 200 D 1 2 3 4 5 6 7 F F E Private Phone 2...

Reviews: