background image

[DiaDENS-PC]  

www.jpastar.com

amplitude. This regime produces effects opposite to those of the regime "7710". It is effective when used as a 

preventive and treatment of physical and mental fatigue, for emotional stress, or depressions. 

 

5.1.4. The MED programme

 

The 

MED

 (Minimal Effective Dose) programme will be applied for intense physical or mental work; in physical or 

mental strain, in chronic fatigue syndrome, difficulties getting up in the morning, drowsiness, difficulty concentrating, 
and as preventive measure in cold and flu seasons.

 

 

5.5  FOLL Regime

 

FOLL  regime  is  based  on  the  method  developed  by  R.  Foil.  The  Foil  method  is  a  method  of  electropuncture 

diagnosis through electric channels for evaluation of functional condition of all internal organs of the human body. The 
method is also intended for testing and selection of individual medicinal, homeopathic preparations and biologically 
active additives.

 

Attention! 

The  regime  is  intended  for  evaluation  of  functional  condition  of  the  organs  and  systems 

rather than diagnosings. We may discuss conditions when the function is reduced, normal or activated.

 

 
The studies with the Foil method can be performed in several ways:

 

1.  Express-evaluation of the functional condition by the end points of the meridians (which is enough for 

performing diagnostic procedures at home) (Supplement 1, Fig. 1, 2); 

2.  Evaluation of the functional condition by control or other points of meridians*; 
3.  Medicinal testing 

Preparing for diagnosis

 

Two days prior to the diagnosis procedure, it is recommended that patient avoids tonics. On the day of the diagnosis, 

two hours before the procedure, the patient should avoid taking coffee, or tea, or food. Immediately before the pro-
cedure, it is recommended for patient to sit in a comfortable position and relax for about 15 minutes.

 

Prior to the session, remove all devices generating high-frequency electromagnetic fields (cell telephones, pagers, 

high-frequency ovens, TV-sets, irons, etc.). The patient will have to remove jewelry, glasses, and a watch. During the 
examination, the patient must be seated or reclining comfortably. 

Medicinal testing

 

The first measurement of the parameters will be performed with no medication.

 

Then the substance to be tested will be placed into the contour of the passive diagnostic electrode and the 

measurement will be repeated for the same points.

 

Attention! 

Do not place the samples under study into the passive electrode without packaging them first, as it is not 

recommended to wash the electrode, whereas particles of the sample remaining on the electrode surface will distort 
values of measurements obtained in subsequent diagnosis.

 

 
Comparing the parameters obtained, we may conclude on the fact how the substance under study affects the 

state of the meridians.

 

If necessary, we may continue the testing a different medicine.

 

Analysis of the results obtained

 

For the express-diagnosis, the normal values are about 50-65 units. Values over 65 units indicate hyperfunction of 

inflammation; whereas values below 50-30 units are specific for hypofunction of degeneration condition; values lower 
than 20 units indicate atrophy or complete failure of the function.

 

For the express-diagnosis using the arrow drop effect, the difference between the maximal and subsequent values 

must not exceed 5 units (irrespective of the measurement sign); if the difference is over 5 units (irrespective of the 
measurement sign), this will indicate activation of pathological processes in the organs located at a given meridian.

 

For medicinal testing: if the parameters obtained for the sample under study are within the range of normal values 

(or  nearly  normal)  for  a  given  patient,  then  the  substance  under  study  will  produce  optimal  effect  upon  the 
organism. And if the parameters differ considerably from the average value, then the substance under study will not 
be recommended for this particular patient.

 

5.6. BIOFOLL Regime

 

The BIOFOLL regime is based on the method developed by R. Foil (see Section 5.5. FOLL Regime). BIOFOLL is a 

modification of the R. Foil classic method; it differs by preliminary determining of testing voltage in In-Tan point. 

Summary of Contents for DiaDENS-PC

Page 1: ...ator with inner and remote electrodes for stimulation of Biologically Active Points BAP and Biologically Active Zones BAZ and for electropuncture diagnosis DiaDENS PC OPERATION INSTRUCTIONS brief edition USA Distributor JPA 888 709 9457 www jpastar com ...

Page 2: ...nd troubleshooting 8 Storage and transportation 9 Utilisation 10 Manufacturer warranty 11 Certificate of acceptance Part 2 Instruction for operation 1 General considerations 2 The conditions for performing the treatment 3 The electrostimulation intensity 4 The treatment methods 5 Regimes of operation 6 Recommended treatment zones and points Supplement 1 Atlas of recommended treatment zones and poi...

Page 3: ... of the impulse positive part V not exceeding 30 10 amplitude of the impulse negative part V without load 350 70 withload 20 5 kOhm 300 70 2 2 The device has the frequencies of impulse sequence settings in Hz as follows 2 2 1 Range 1 10 2 including MED and SCREENING regimes 20 2 60 2 77 2 77 Hz 2 and 10 Hz 2 modulated with frequency 2 0 1 Hz 77 Hz 2 with modulation by amplitude 140 5 200 5 2 2 2 R...

Page 4: ...rrent 4 3 During stimulation the patient must not be connected to any high frequency electrical device other than personal computer connected with a special cable provided in complete as sembly 4 4 During stimulation or diagnosis with the computer connected to the device one must not simultaneously touch the patient and the computer frame 4 5 Warning of potentially dangerous factors simultaneous u...

Page 5: ...ng the device on key 10 Off or Выкл for switching the device off 5 4 The device has also slots as follows Fig 1 slot 11 for connection of remote therapeutic electrodes and connecting to personal computer slot 12 for connection of diagnostic electrodes 6 TECHNICAL MAINTENANCE 6 1 Daily technical maintenance must consist of the operations as follows visual inspection of the device disinfection For c...

Page 6: ...ipe with tampon wetted with water No contact be tween the device and the remote diagnostic elec trode Check the con tact of the slot 12 Fig 1 Device performs no measuring in the FOLL BIOFOLL and BIORE PER MiniAC regimes Dry skin Swipe with tampon wetted with water Disrupted connec tion between the device and per sonal computer Check the contact 1 Slot 11 Fig 1 2 Slot of computer connection Device ...

Page 7: ...supply will be determined by its manufacturer 10 4 Retailer manufacturer or organization functioning as retailer manufacturer based on the contract concluded with it is not liable for defects if they occur after delivery of the device to the user as a consequence of 1 violating the rules of transportation storage maintenance or operation by the user as these rules are indicated in this Operation I...

Page 8: ...s digestive diseases cardiovascular skeletal muscle uro genital nervous endocrine systems ОТО diseases eyes and skin diseases in adults and children rehabilitation and recovery following treatment surgical interventions and lesions effects of unfavourable pathogenic factors stress intense physical or psycho emotional loads other unfavourable conditions CONTRAINDICATIONS Absolutee individual intole...

Page 9: ...ion power levels might be increased or decreased depending on the patient sensitivity changes and elimination of the pain syndrome 4 OPERATING METHODS The dynamic electroneurostimulation will be performed in three ways stable labile and labile stable The stable effect fixed position of the electrode will be used when treating small zonal spots In the labile way the built in electrodes of the stimu...

Page 10: ... biologically active points and zones with altered parameters revealed after electropuncture diagnosis performed by the method of FOLL or BIOFOLL Treatment formula and choice of optimal frequency will be performed individually after analyzing the obtained diagnosis data Additionally these frequencies can be used with the built in electrode of the device with due consideration of the indications pr...

Page 11: ...hritis arthrosis Bechterew s disease depressions spine lesions osteochondrosis 9 7 Arthritis arthrosis sciatica gout nephrosclerosis uremia rheumatism 9 8 Toxic and infectious damages to the liver hepatitis cirrhosis A V Samokhin Yu V Gotovsky The electropuncture diagnosis by the R Foil technique M The Centre of Intellectual Medical Systems IMEDIS 2003 512 p 10 20 Hz low frequencies They will be u...

Page 12: ...tient will have to remove jewelry glasses and a watch During the examination the patient must be seated or reclining comfortably Medicinal testing The first measurement of the parameters will be performed with no medication Then the substance to be tested will be placed into the contour of the passive diagnostic electrode and the measurement will be repeated for the same points Attention Do not pl...

Page 13: ...n the patient must be seated or reclining comfortably the methods of diagnosis by the control and other points of channels are described in detail in the reference to this topic These techniques in their operation with the device do not differ from the express evaluation but demand serious theoretical and practical training of the operator physician performing the diagnosis and will not be discuss...