[DiaDENS-PC]
www.jpastar.com
Table 4
Simultaneous
pressing of the ("F" or
«
Ф
») and ("On" or
«
Вкл
») keys
(“B" or «
Б
»)
key
Simultaneous
pressing of the ("B"
or «
Б
») and ("On" or
«
Вкл
») keys
FOLL
(«
ФОЛЛЬ
»)
BioFOLL
(«
БиоФОЛЛЬ
»)
BIOREPER
(«
БИОРЕПЕР
»)
MiniAC
5.1.1 TEST Regime
TEST regime is intended for evaluation of functional condition of the body organs and systems by means of
searching for zones where the skin electrical resistance will sharply differ from adjacent areas (the latent trigger
zones (it is also intended for treatment of the skin areas symmetrical to the complaint projection (the symmetry
principle).
Attention!
In the TEST regime, search for latent trigger zones will be performed rather than diagnosis.
The energy range: minimal or comfortable. The operating method: stable (the electrodes will be shifted after
receiving a sound signal).
5.1.2. The SCREENING regime
The SCREENING regime provides quick evaluation of the zone condition prior to and after DENS treatment. The
SCREENING regime is intended for fast search of latent trigger zones. One measurement of the skin surface
resistance occurs within first five seconds.
5.1.3. The THERAPY regime
The THERAPY regime OPERATES:
- at frequencies of 1.0 to 9.9 Hz (with the minimal step 0.1 Hz);
- at frequencies of 10, 20, 60, 77, 140 and 200 Hz;
- in therapeutic regimes 77.10 and 77AM.
At operation in THERAPY regime, both the zonal (with the aid of inbuilt electrodes) and pointed (with the aid of
remote electrode) action.
Recommendations for choosing therapeutic frequencies:
-
1.0-9.9 Hz - "infraslow".
These will be used for action upon
biologically active points and zones with altered parameters revealed after electropuncture diagnosis
performed by the method of FOLL or BIOFOLL. Treatment formula and choice of
optimal frequency will be
performed individually, after analyzing the obtained diagnosis data. Additionally, these frequencies can be used
with the built-in electrode of the device with due consideration of the indications presented in Table 5.
Table 5
The list of frequencies used in the device DiaDENS-PC for some diseases,
syndromes and symptoms within the range 1..9.9 Hz*
Frequency, Hz
Characteristics of the pathological condition
1.2
Autoimmune diseases, tachycardia, knee joint weakness
1.6
Arthritis-arthrosis
1.7
Acne, abscess, hypotension, dermatitis, parodontosis, sympathetic-tonic action,
furunculosis, eczema
2.2
Fatigue, pustular eczema
2.5
Insomnia, vegetative disorders, hypermenorrhoea, headache associated with the
nasal sinus diseases, haemorrhages, brain contusions, lesions, menor-rhages,
uterine myoma, oedemas, toxic and infectious liver damages, hepatitis, cirrhosis,
parodontosis, sinusitis, contusions, eczema
2.6
Virile syndrome, haemorrhoids, headaches in liver diseases, intestinal headache,
dermatitis, impotence
2.8.
Nephritis, nephrolithiasis, renal colic, nephrosclero-sis, uremia
2.9
Rhinitis, sinusitis
3.3
Arteriosclerosis, hypertension, otosclerosis, toxic and infectious liver damages
(hepatitis, cirrhosis), nephrolithiasis, renal colic, nephrosclerosis, uremia, nephritis,
furunculosis, hypertension against the background of atherosclerosis
3.5
Gall-stone disease, nephrolithiasis, renal colic, knee joint weakness, menorrhages
3.6
Inflammation, moodiness, irritability
3.8
Allergy, haemorrhoids, spasms of various genesis
3.9
Neuralgia, sleep disorders (the phase of falling asleep)