Table 4

 

Simultaneous  

pressing of the ("F" or 

«

Ф

») and ("On" or 

«

Вкл

»)   keys

 

(“B" or «

Б

») 

key

 

Simultaneous 

pressing of the ("B" 

or «

Б

») and ("On" or 

«

Вкл

») keys

 

FOLL 

ФОЛЛЬ

»)

 

BioFOLL 

БиоФОЛЛЬ

»)

 

BIOREPER 

БИОРЕПЕР

») 

MiniAC

 

 

5.1.1 TEST Regime

 

TEST regime is intended for evaluation of functional condition of the body organs and systems by means of 

searching for zones where the skin electrical resistance will sharply differ from adjacent areas (the latent trigger 
zones (it is also intended for treatment of the skin areas symmetrical to the complaint projection (the symmetry 
principle). 

Attention!

 

In the TEST regime, search for latent trigger zones will be performed rather than diagnosis.

 

The energy range: minimal or comfortable. The operating method: stable (the electrodes will be shifted after 

receiving a sound signal).

 

5.1.2. The SCREENING regime 

The SCREENING regime provides quick evaluation of the zone condition prior to and after DENS treatment. The 

SCREENING regime is intended for fast search of latent trigger zones. One measurement of the skin surface 
resistance occurs within first five seconds.

 

5.1.3. The THERAPY regime

 

The THERAPY regime OPERATES:

 

-  at frequencies of 1.0 to 9.9 Hz (with the minimal step 0.1 Hz); 
-  at frequencies of 10, 20, 60, 77, 140 and 200 Hz; 
-  in therapeutic regimes 77.10 and 77AM. 
At operation in THERAPY regime, both the zonal (with the aid of inbuilt electrodes) and pointed (with the aid of 

remote electrode) action.

 

Recommendations for choosing therapeutic frequencies:

 

1.0-9.9 Hz - "infraslow".

 These will be used for action upon 

biologically active points and zones with altered parameters revealed after electropuncture diagnosis 
performed by the method of FOLL or BIOFOLL. Treatment formula and choice of

 

optimal frequency will be 

performed individually, after analyzing the obtained diagnosis data. Additionally, these frequencies can be used 
with the built-in electrode of the device with due consideration of the indications presented in Table 5.

 

Table 5

 

The list of frequencies used in the device DiaDENS-PC for some diseases, 

syndromes and symptoms within the range 1..9.9 Hz*

 

 

Frequency, Hz

 

Characteristics of the pathological condition

 

1.2

 

Autoimmune diseases, tachycardia, knee joint weakness

 

1.6

 

Arthritis-arthrosis

 

1.7

 

Acne,  abscess,  hypotension,  dermatitis,  parodontosis,  sympathetic-tonic  action, 
furunculosis, eczema

 

2.2

 

Fatigue, pustular eczema

 

2.5

 

Insomnia, vegetative disorders, hypermenorrhoea, headache associated with the 

nasal  sinus  diseases,  haemorrhages,  brain  contusions,  lesions,  menor-rhages, 
uterine myoma, oedemas, toxic and infectious liver damages, hepatitis, cirrhosis, 
parodontosis, sinusitis, contusions, eczema

 

2.6

 

Virile  syndrome,  haemorrhoids,  headaches  in  liver  diseases,  intestinal  headache, 

dermatitis, impotence

 

2.8.

 

Nephritis, nephrolithiasis, renal colic, nephrosclero-sis, uremia

 

2.9

 

Rhinitis, sinusitis

 

3.3

 

Arteriosclerosis,  hypertension,  otosclerosis,  toxic  and  infectious  liver  damages 

(hepatitis, cirrhosis), nephrolithiasis, renal colic, nephrosclerosis, uremia, nephritis, 
furunculosis, hypertension against the background of atherosclerosis

 

3.5

 

Gall-stone disease, nephrolithiasis, renal colic, knee joint weakness, menorrhages

3.6

 

Inflammation, moodiness, irritability

 

3.8

 

Allergy, haemorrhoids, spasms of various genesis

 

3.9

 

Neuralgia,   sleep   disorders   (the   phase   of  falling asleep)

 

Summary of Contents for DiaDENS-PC

Page 1: ...ator with inner and remote electrodes for stimulation of Biologically Active Points BAP and Biologically Active Zones BAZ and for electropuncture diagnosis DiaDENS PC OPERATION INSTRUCTIONS brief edition USA Distributor JPA 888 709 9457 www jpastar com ...

Page 2: ...nd troubleshooting 8 Storage and transportation 9 Utilisation 10 Manufacturer warranty 11 Certificate of acceptance Part 2 Instruction for operation 1 General considerations 2 The conditions for performing the treatment 3 The electrostimulation intensity 4 The treatment methods 5 Regimes of operation 6 Recommended treatment zones and points Supplement 1 Atlas of recommended treatment zones and poi...

Page 3: ... of the impulse positive part V not exceeding 30 10 amplitude of the impulse negative part V without load 350 70 withload 20 5 kOhm 300 70 2 2 The device has the frequencies of impulse sequence settings in Hz as follows 2 2 1 Range 1 10 2 including MED and SCREENING regimes 20 2 60 2 77 2 77 Hz 2 and 10 Hz 2 modulated with frequency 2 0 1 Hz 77 Hz 2 with modulation by amplitude 140 5 200 5 2 2 2 R...

Page 4: ...rrent 4 3 During stimulation the patient must not be connected to any high frequency electrical device other than personal computer connected with a special cable provided in complete as sembly 4 4 During stimulation or diagnosis with the computer connected to the device one must not simultaneously touch the patient and the computer frame 4 5 Warning of potentially dangerous factors simultaneous u...

Page 5: ...ng the device on key 10 Off or Выкл for switching the device off 5 4 The device has also slots as follows Fig 1 slot 11 for connection of remote therapeutic electrodes and connecting to personal computer slot 12 for connection of diagnostic electrodes 6 TECHNICAL MAINTENANCE 6 1 Daily technical maintenance must consist of the operations as follows visual inspection of the device disinfection For c...

Page 6: ...ipe with tampon wetted with water No contact be tween the device and the remote diagnostic elec trode Check the con tact of the slot 12 Fig 1 Device performs no measuring in the FOLL BIOFOLL and BIORE PER MiniAC regimes Dry skin Swipe with tampon wetted with water Disrupted connec tion between the device and per sonal computer Check the contact 1 Slot 11 Fig 1 2 Slot of computer connection Device ...

Page 7: ...supply will be determined by its manufacturer 10 4 Retailer manufacturer or organization functioning as retailer manufacturer based on the contract concluded with it is not liable for defects if they occur after delivery of the device to the user as a consequence of 1 violating the rules of transportation storage maintenance or operation by the user as these rules are indicated in this Operation I...

Page 8: ...s digestive diseases cardiovascular skeletal muscle uro genital nervous endocrine systems ОТО diseases eyes and skin diseases in adults and children rehabilitation and recovery following treatment surgical interventions and lesions effects of unfavourable pathogenic factors stress intense physical or psycho emotional loads other unfavourable conditions CONTRAINDICATIONS Absolutee individual intole...

Page 9: ...ion power levels might be increased or decreased depending on the patient sensitivity changes and elimination of the pain syndrome 4 OPERATING METHODS The dynamic electroneurostimulation will be performed in three ways stable labile and labile stable The stable effect fixed position of the electrode will be used when treating small zonal spots In the labile way the built in electrodes of the stimu...

Page 10: ... biologically active points and zones with altered parameters revealed after electropuncture diagnosis performed by the method of FOLL or BIOFOLL Treatment formula and choice of optimal frequency will be performed individually after analyzing the obtained diagnosis data Additionally these frequencies can be used with the built in electrode of the device with due consideration of the indications pr...

Page 11: ...hritis arthrosis Bechterew s disease depressions spine lesions osteochondrosis 9 7 Arthritis arthrosis sciatica gout nephrosclerosis uremia rheumatism 9 8 Toxic and infectious damages to the liver hepatitis cirrhosis A V Samokhin Yu V Gotovsky The electropuncture diagnosis by the R Foil technique M The Centre of Intellectual Medical Systems IMEDIS 2003 512 p 10 20 Hz low frequencies They will be u...

Page 12: ...tient will have to remove jewelry glasses and a watch During the examination the patient must be seated or reclining comfortably Medicinal testing The first measurement of the parameters will be performed with no medication Then the substance to be tested will be placed into the contour of the passive diagnostic electrode and the measurement will be repeated for the same points Attention Do not pl...

Page 13: ...n the patient must be seated or reclining comfortably the methods of diagnosis by the control and other points of channels are described in detail in the reference to this topic These techniques in their operation with the device do not differ from the express evaluation but demand serious theoretical and practical training of the operator physician performing the diagnosis and will not be discuss...