MANUAL DE INSTRUCCIONES
CODE 80328 REV A
12/2021 Pag.: 25
J
.P. SELECTA s.a.u.
Autovía A-2 Km 585.1 Abrera 08630 (Barcelona) España
Tel 34 937 700 877 Fax 34 937 702 362
e-mail: [email protected] - website: http://www.grupo-selecta.com
To put or remove the cover, hold it as seen on the picture and turn the
central nut clockwise to place it or anti clockwise to remove it.
For an easy windbreak cover extraction, hold it like in the picture and
pull up.
6.5 Power supply connection
Installation of the mains must be performed by qualified personnel.
Connect the equipment to the main power, checking that the power
voltage is as indicated on the machine’s specification plate.
Install an emergency disconnect switch (20Amp) to cut power supply
in case of malfunction.
This switch must be installed at a minimum distance of 10m from the
centrifuge (preferably outside the room where the centrifuge is).
Sections and colours of the connection cable:
Brown cable 6mm:
Phase
Black cable 6mm:
Phase
Blue cable 6mm:
Neutral
Yellow/green cable 6mm:
Earth
Do not use the equipment if it is not connected to earth.