Joy-it VAX-1100 Manual Download Page 6

Connection between a relay and the VAX1100

You must note among the usage with a relay that the relay must be 

designed for the expected voltage and current in that specific

construction.

There are displayed 3 possible symbols which are designed for the 

verification of the connection. These symbols have this meaning:

6. OPERATION

Wireless connection is successfully established

Corded connection is successfully established

Connection failed or is not connected

Key

Function

“OUT“

Hereby, you can switch the output. In order that it 

works, the relay must be controlled.

“NCP“

Hereby, the protection against the negative current 

can be activated. With “OK“ you can change the 

value, if the value is “0“, the function is deactivated. 

This function shifts the relay to interrupt the circuit.

“OCP“

Hereby, the protection against overcurrent can be 

activated. With “OK“ you can change the value, if the 

value is “0“, the function is deactivated. This function 

shifts the relay to interrupt the circuit.

power 

source

load

battery

charger

Summary of Contents for VAX-1100

Page 1: ...sitate to contact us The measuring instruments of the VAX series are multimeter which transmit the measurement results to the display via a wireless 2 4 GHz technology A TFT LCD shows the measured val...

Page 2: ...its 5 Hz Up to 10 m ca 0 4 W Charge indicator Measuring range power Resolution power Measuring range ampere hours Resolution ampere hours Measuring range watt hours Resolution watt hours Measuring ran...

Page 3: ...e measuring instrument can be connected with the display via a cable or wireless If the connection is wireless there are two opportunities to power the display You can use the mUSB port 5 V or the JST...

Page 4: ...tput relay resetting charge status system settings address settings channel setting language setting 5 CONNECTION If the instrument is integrated in the circuit like in the left illustration it is pos...

Page 5: ...he charging process of batteries For a measuring range from 0 to 100 V the instrument must be connected like that These illustrations display how the VAX1100 must be connected for a mea suring range f...

Page 6: ...essfully established Connection failed or is not connected Key Function OUT Hereby you can switch the output In order that it works the relay must be controlled NCP Hereby the protection against the n...

Page 7: ...be adjusted BRI You can adjust here the brightness of the display LNG You can change here the language Important To go to the LNG option you must enter ADR and hold down the down arrow key for 3 secon...

Page 8: ...wing internet addresses www simac gmbh de CE com vax1030 pdf www simac gmbh de CE com vax1100 pdf Information on transmission power and frequency band of COM VAX1030 Frequency band 2412 2472 MHz Max t...

Reviews: