2. TECHNICAL SPECIFICATIONS

Model

VAX-1030

VAX-1100

Measuring range voltage

Resolution voltage

Measuring range current

Resolution current

Relay

0 - 100 V

0,01 V

0 - 100 V

0,01 V

0 - 100 A

0 - 30 A

0,01 A

Internal

0,1 A

External (optional)

Measuring range 

temperature

-20 - 120 °C

0 - 100 %

0 - 200 kW

0,001 W

0 - 2000 AH

0,001 AH

0 - 4000 kWH

0,001 WH

0 - 99 days

1 seconds

± 2 % + 3 digits

± 5 % + 10 digits

5 Hz

Up to 10 m

ca. 0,4 W

Charge indicator

Measuring range power

Resolution power

Measuring range

 ampere hours

Resolution ampere hours

Measuring range 

watt-hours

Resolution watt-hours

Measuring range time

Resolution time

Accuracy voltage

Accuracy current

Sampling rate

Range, wireless

Power consumption 

measuring instrument

Power consumption 

display

NCP

OCP

OVP

LVP

delay of 

protection settings

0,5 W

0 - 300 A (setting of negative overcurrent protection)

0 - 300 A (setting of overcurrent protection)

0 - 100 V(setting of overvoltage)

0 - 100 V(setting of undervoltage)

0 - 10 s

Summary of Contents for VAX-1100

Page 1: ...sitate to contact us The measuring instruments of the VAX series are multimeter which transmit the measurement results to the display via a wireless 2 4 GHz technology A TFT LCD shows the measured val...

Page 2: ...its 5 Hz Up to 10 m ca 0 4 W Charge indicator Measuring range power Resolution power Measuring range ampere hours Resolution ampere hours Measuring range watt hours Resolution watt hours Measuring ran...

Page 3: ...e measuring instrument can be connected with the display via a cable or wireless If the connection is wireless there are two opportunities to power the display You can use the mUSB port 5 V or the JST...

Page 4: ...tput relay resetting charge status system settings address settings channel setting language setting 5 CONNECTION If the instrument is integrated in the circuit like in the left illustration it is pos...

Page 5: ...he charging process of batteries For a measuring range from 0 to 100 V the instrument must be connected like that These illustrations display how the VAX1100 must be connected for a mea suring range f...

Page 6: ...essfully established Connection failed or is not connected Key Function OUT Hereby you can switch the output In order that it works the relay must be controlled NCP Hereby the protection against the n...

Page 7: ...be adjusted BRI You can adjust here the brightness of the display LNG You can change here the language Important To go to the LNG option you must enter ADR and hold down the down arrow key for 3 secon...

Page 8: ...wing internet addresses www simac gmbh de CE com vax1030 pdf www simac gmbh de CE com vax1100 pdf Information on transmission power and frequency band of COM VAX1030 Frequency band 2412 2472 MHz Max t...

Reviews: