Date:
Manual:
Rev:
2020-02-04
M395
F2
JOWA Ag-S
Silver Ion Water Treatment System
Standard
25/32
Water is going into the
tank, however, the
Ag-S is not indicating
silver ions are being
produced. (Tank
recirculate mode)
Not enough water has
entered the tank to run the
unit for a minimum of 2
minutes
Wait until more water has
entered the tank
If a quicker response is
desired then adjust the
tank size, see Section
5.4.1
6.1
Resetting the Ag-S
In the rare case that the Ag-S needs to be reset it has three options:
Control panel
– This choice would be used if a remote display is used and that
display is not working correctly. It restarts only the display board that is connected
directly to the panel being operated. No setup data is lost during this reset.
Ag-S device
– This choice will reset the main board and will reset the display board
that is directly connected to it. If no remote display is used this will be the panel that
is being operated. No setup data is lost during this reset.
Ag-S to factory def
– This is a reset of all the settings within the device to the factory
default. All user settings will be erased and must be reentered. A second warning
screen is displayed if this option is selected to confirm that you want to reset to
factory defaults. After selecting this you will need to go back to section 5.4.1 and
enter all the setup parameters.