22
ENGLISH
10�1�2 Menu description
ICON
FUNCTION
DESCRIPTION
VALUES
Power
Setting working power.
1–5
Ventilation:
*(if provided)
Setting of air fan power in room
OFF*, 1–5; Auto; Hi.
Temperature
Displays the room temperature and allows for programming the desired
temperature.
from 6°C to 51°C
Fuel
Physical measurement by Level Tronic sensor
FULL – OFF
Time breaker switch Activates and deactivates the time breaker switch. When the control clock
is engaged, the icon is displayed constantly.
ON – OFF
ICON
FUNCTION SUBMENU
DESCRIPTION
VALUES
Adjustment
[1]
Weekly scheduler
Assignment of programs (max. 3) to different days
of the week.
from [d1] to [d7]
[2]
Programs
Configuration of programs.
from [P1] to [P6]
[3]
Clock/date
Setting the date and time.
[4]
Hours remaining
Displays the number of hours remaining until the
next recommended maintenance. The “Hi” value
signifies a number greater than 999 hours.
[5]
System information
Displays the current software version.
[6]
Inactive function
[7]
Eco function
Activates or deactivates Eco mode, which enables
automatic firing and extinguishing depending on
ambient temperature (only in configuration 1).
OFF; Eco
[8]
Reignition delta
The difference in degrees relative to room
temperature, below which the stove will reignite
(only in configuration 1).
from 0,5°C to 5,0°C
[9]
Anti-freeze protection
temperature
The minimum temperature below which the stove
is fired up (only in configuration 1).
OFF;
from 3°C to 20°C
[10]
Keyboard lock
Configuration of button locking
OFF; Lo; Hi
[11]
Screen brightness
Sets the brightness level of the screen.
OFF;
from 1 to 5
[12]
Display mode
Configuration of data display.
OFF;
from 1 to 4
[13]
Sound signaller
volume
Setting of the sound signaller's volume.
OFF;
from 1 to 5
[14]
Pellet type
3 different pellet types can be set.
from 1 to 3
[15]
Inactive function
[30]
Fitter’s menu
Changes/displays stove configuration.
PWD: „54”
[40]
Service menu
Menu intended for technical service.
Submenu [30] and [40] and the Configuration menu are password protected and intended solely for the technical service.
10�2 USING THE CONTROL KEYBOARD
• Touching the arrow keys scrolls through different
menus, which are highlighted one by one.
• To change the settings of a given function, it is enough
to press the button when the function is displayed
and change the value using the keys.
• Press the key again to confirm the change.
• In general, all flashing parameters can be changed using
the keys.
• The “Cancel” button makes it possible to cancel a
change; pressing it for a long time displays the code of
the alarm that may have been activated.