Jøtul Chimney system
Standard assembly, internal
The chimney is installed from the bottom up.
Start by measuring the hole in the ceiling based on
the fireplace’s flue connecting piece. Cut out the hole
in the ceiling to ensure the correct safety distance to
any flammable material.
If necessary, install an adapter on the fireplace’s flue
connecting piece.
If the fireplace does not have a protection grid for
sweep ball, you are recommended to install one (ac-
cessory) in the fireplace’s connecting piece.
Then position the ceiling plate with the painted side
facing down towards the fireplace. Install the connect-
ing piece on the fireplace and then modules, fully and
semi-insulated.
Tap together the inner tube using a wooden block
during the course of the installation.
Then install the connecting piece’s wide ring over the
connecting piece to conceal the bare flue pipe. Leave
a 10 mm air gap at the bottom by the fireplace.
NB: Ensure that the tongue/groove system is pressed
firmly together; also applies to the cladding pipe.
(evt. adapter)
Innertakplate
(Kulefanger ved behov)
300 mm
300 mm
(evt. adapter)
Innertakplate
Insulated modules
Uninsulated modules
Start by measuring the hole in the ceiling based on
the fireplace’s flue connecting piece. Cut out the hole
in the ceiling to ensure the correct safety distance to
any flammable material.
Start by installing modules from the bottom by the
stove. Some stoves need an adapter at the bottom in
order for installation to be successful.
Then install the ceiling plate with the painted side
facing down towards the fireplace.
Install the connecting piece on the fireplace and then
modules.
Tap together the inner tube using a wooden block
during the course of the installation.
Observe a distance of 300 mm to any flammable ma-
terials (this applies to the uninsulated part).
NVI 2000 STANDARD INSTALLATION
Ceiling plate
(adapter if necessary)
(Protection grid for sweep ball if
necessary)
FLUE PIPE
INSULATION
INSULATION
FLUE PIPE
Ceiling plate
(adapter if necessary)