background image

23

ENGLISH

1.0 Relationship with the 
authorities

Jøtul FS 

165

 – I 

400

 FL is a freestanding product with Jøtul I 

400

 FL as the burn chamber, which can be positioned against 

inflammable walls at the distances described in 

Fig. 1.

Installation of the fireplace must be according to local codes 
and regulations in each country. All local regulations, including 
those that refer to national and European standards, shall be 
complied with when installing the product.

Installation instructions for the surround are included.
Installation and user instructions for the insert are enclosed 
with the product.
For day-to-day use, maintenance, servicing, etc., please see this 
document. The installation may only be used once it has been 
inspected and a certificate of completion has been issued. 

Prior to using the product the installation must be approved by 
a qualified person. 

The classification label for the free-standing products is enclosed 
with the surround’s installation instructions and is to be placed 
on the backside of upper back plate 

(Fig. 2 - position 15)

.

This contains information about  identification and 
documentation for the product. 

2.0 Technical data

Weight, surround:  

Approx. 350 kg

Weight, burn chamber:  

Approx. 110 kg

Height: 1835 

mm

Width: 872 

mm

Depth: 493 

mm

Height, centre smoke outlet: 

1587 mm

(Technical data for burn chamber - see installation manual for 
Jøtul I 

400 

FL)

Optional equipment

•  Sidestone with hole 

 

cat.no. 361050

• 

Ash 

solution 

  cat.no. 

341280

•  Kit for outside air connection 

cat.no. 341279

Table of contents

1.0    Relationship with the authorities ............. 23

2.0   Technical data ............................................. 23

3.0    Parts of the surround ................................. 25

4.0   Prior to installation ....................................26

5.0   Mounting ....................................................28

6.0   Installation completed ............................... 32

6.0   Maintenance .............................................. 32

7.0   Optional equipment .................................. 32

 

On all our products there is a label 
indicating the serial number and 
year. Write this number in the 
place indicated in the installation 
instructions. 

Always quote this serial number 
when contacting your retailer or 
Jøtul.

les combustibles recommandés.

Respectez les consignes d'utilisation. Utilisez uniquement

Verwenden Sie nur empfohlenen Brennstoffen.

Montage- und Bedienungsanleitung beachten. 

Follow user`s instructions. Use only recommended fuels.

standard

Certificate/

The appliance can be used in a shared flue.

Minimum distance to adjacent combustible materials:

Emission of CO in combustion products

Serial no: Y-xxxx, Year: 200x

Manufacturer:

N-1602 Fredrikstad
Norway

Jøtul AS
POB 1441

Sweden

EUR

Intermittent

Nominal heat output      

Norway

Country

Operational type

Fuel type

Operation range

Efficiency

Klasse II

Classification

Standard

Flue gas temperature             

Room heater fired by solid fuel

Product:

Jøtul

SP Sveriges Provnings- och

221546

Forskningsinstitut AB
SP Swedish National 
Testing and Research
Institute

:

Approved by

:

:

:
:

:
:

:

Minimum distance to adjacent combustible materials:

OGC 

SP 

EN 

Serial no.

Summary of Contents for FS 165-I 400 FL

Page 1: ...tung f r sp tere Zwecke sorgf ltig aufzubewahren J tul FS 165 I 400 FL Manual Version P02 J tul FS 165 I 400 FL NO Monterings og bruksanvisning 4 FI Asennus ja k tt ohje 14 UK Installation and Operati...

Page 2: ...ominel varmeafgivelse Verkningsgrad vid nominell v rmeavgivning Hy tysuhde nimellisl mp teholla 74 S rskilte forholdsregler n r ovnen monteres installeres eller vedlikeholdes S rlige forholdsregler de...

Page 3: ...llation ou l entretien de l appareil x Cualquier precauci n espec fica que deba tenerse en cuenta durante el montaje instalaci n o mantenimiento del equipo de calefacci n x Precauzioni specifiche da p...

Page 4: ...burn chamber see installation manual for J tul I 400 FL Optional equipment Sidestone with hole cat no 361050 Ash solution cat no 341280 Kit for outside air connection cat no 341279 Table of contents...

Page 5: ...cording to EN 13240 Product J tul FS 165 I 400 FL Position 6 3 pcs ca 35 mm 496 1835 1587 1258 1587 606 237 237 2 2 0 50 x y 400 R a d i a t i o n z o n e 1000 287 Min m l gulvplate measurement floorp...

Page 6: ...25 3 0 Parts of the surround Fig 2 ENGLISH...

Page 7: ...acket 4 4 pcs 24 Screw countersink unb M6x16 8 pcs 25 Smoke outlet cover 2 pcs 26 Heat shield top 1 pcs 27 Distance piece 4 pcs 4 0 Prior to installation 4 1 Foundations You need to make sure the foun...

Page 8: ...tallation instructions Fig 3 F E D C A B Once the burn chamber has been unpacked take the box containing the smoke bell log retainer Fig 3 C gasket and bag of screws out of the burn chamber Then remov...

Page 9: ...s by unscrewing the two screws M8x20 mm on either side Fig 5 A of the burn chamber Fig 6 1 ca 35 mm A B C Lay the burn chamber carefully down on its back Fig 6 You can put the cardboard packaging on t...

Page 10: ...installation is correct Fig 9 1 When using an External air connection cat no 341279 this has to be fitted now Fig 10 Bracket 3 Bracket 6 Bracket 1 Bracket 5 Bracket 4 Bracket 2 Bracket 2 Fig 11 A B 3...

Page 11: ...own Fig 13 C Fig 14 A B 1 Mount the first rear plate to bracket 6 that is placed under the first layer of soap stone 2 Mount bracket 3 from the inside through the back plate Fig 14 A Use a hammer and...

Page 12: ...hall rest on the attachment bracket Fig 19 B C A 1 Install the flue pipe Top smoke outlet Fig 19 A or rear smoke outlet Fig 19 B If a rear smoke outlet Remove the knockout in the rear plate Fig 19 C E...

Page 13: ...rtune to find scratches in the surface these may be polished out using a fine sandpaper If deeper scratches are present a paste made of powdered soap stone and water glass sodium silicate can be made...

Page 14: ...83...

Page 15: ...f rences d aspect de couleur et d accessoires par rapport au pr sent document Kvalitet V r kvalitetspolitikk skal gi kundene den trygghet og kvalitetsopplevelse som J tul har st tt for siden bedriften...

Reviews: