General Maintenance

Regular maintenance will assure proper perfor-
mance and prolong the life of your fireplace insert..
The following procedures do not take long and are
generally inexpensive. When done consistently,
they will help increase the life of your fireplace
insert and assure satisfactory performance.

• Thoroughly clean the insert.  Enamel surfaces

should be cleaned with a moist cloth and
polished dry..

• Empty firebox of all soot and ashes.  Never use a

household vacuum cleaner to remove ashes.
Only a shop vacuum with a metal container is
acceptable and only when you are certain the
ashes are cold.

• Inspect the firebox using a utility light inside and

out for cracks or leaks.  Replace all cracked bricks
and repair leaks with furnace cement.

Removing the Insert for Cleaning

U.S. Direct-connection Only:

1. Disconnect the blower power cord from its

outlet.

2. Open the firebox door and pull the insert out

enough to disengage the surround panel assem-
blies by lifting up off of the brackets.

3. Lift up the Left Cast Iron Baffle to disengage the

locator boss from the Front Air Tube, and pull the
air tube forward and out of the side manifolds.

4. Keeping  the Rear Air Tube in place, push up on the

Right Baffle and remove the Left Baffle.

5. Lift and remove the Right Baffle.

6. Slide the Rear Air Tube to one side to disengage

it from the Side Manifolds.

7. Remove the retainer pin from the Draw-down

Adaptor. Push up on the draw-down bar to
disengage the adaptor from the insert

8. Pull the firebox and cabinet forward as a unit.

The flue connector, liner, and chimney can now
be inspected and cleaned.

9. See page 12 for reassembly procedures.

Gaskets

Check door and glass gaskets for seal integrity.
The gaskets should be soft enough to be somewhat
resilient to the touch. Over time, gaskets will
compress and harden. Replace worn-out or hardened
gaskets with the appropriate size material available
from your local Authorized Jøtul Dealer.

To check the seal of the front doors, close and latch
the doors on a dollar bill and slowly try to pull the
dollar bill free.  The seal is too loose if the bill can be
easily removed.  Adjust the door latch and test again.

Replacement Gaskets

Glass

Glass

Glass

Glass

Glass
LD .250 Fiberglass Rope

66”

200024

Door

Door

Door

Door

Door
LD2 .350 Fiberglass Rope

70”

100038

F

FF

FFrrrrron

on

on

on

onttttt

LD2   .360 Fiberglass Rope

90.5”

117587

Air Manif

Air Manif

Air Manif

Air Manif

Air Manifold,

old,

old,

old,

old, Outer

 Outer

 Outer

 Outer

 Outer

LD2  .250 SA Fiberglass Rope 30”

129644

Air Manif

Air Manif

Air Manif

Air Manif

Air Manifold,

old,

old,

old,

old, Inner

 Inner

 Inner

 Inner

 Inner

.125 x 8 mm Flat SA

24”

127215

Canada Installations (Full Reline):

The chimney liner can be swept directly into a
bucket placed under the flue outlet, with removal of
the two cast iron baffle plates.

1. Lift up the Left Cast Iron Baffle to disengage the

locator boss from the Front Air Tube, and pull the air
tube forward and out of the side manifolds.

2. Keeping  the Rear Air Tube in place, push up on the

Right Baffle and remove the Left Baffle.

3. Lift and remove the Right Baffle.

4. Slide the Rear Air Tube to one side to disengage it

from the Side Manifolds.

5. Reassemble in the reverse order, being sure to

engage the locator bosses on the Left Baffle with
the corresponding holes in the Secondary Air Tubes.

Summary of Contents for C 550 Rockland

Page 1: ...l C 550 Rockland J tul C 550 Rockland Fireplace Insert Keep these instructions for future reference Installation and Operating Instructions for the United States Canada J tul C 550 Rockland Fireplace...

Page 2: ...nd NOTICE YOU SHOULD CONSULT THE AUTHORITY HAVING JURISDICTION IN YOUR LOCALE SUCH AS MUNICIPAL BUILDING DEPARTMENT FIRE DEPARTMENT FIRE PREVENTIOIN BUREAU ETC BEFORE INSTALLATION TO DETERMINE THE NEE...

Page 3: ...te 15 Blower 16 Maintenance Ash Removal 17 Glass Care 17 General Maintenance 18 Gaskets 18 Illustrated Parts Breakdown Parts List 20 21 Miscellaneous Replacement Parts 22 Appendix A Baffle Assembly 23...

Page 4: ...pectant les directives d installation suivantes Consultez les autorit s locales du b timent ou de la pr vention des incendies au sujet des restrictions et exigences relatives aux inspections d install...

Page 5: ...chimney performance Consult your local J tul autho rized dealer regarding specific installation performanceissues Installation Preparation We strongly urge you to have your authorized J tul dealer ins...

Page 6: ...nsert meets U S EPA emission limits for wood heaters sold after July 1990 and is tested and listed to ANSI UL 1482 and CAN ULC S628 93 It is intended for installation in accordance with NFPA 211 or CA...

Page 7: ...equire insulation in order to achieve a UL 1777 or ULC S635 listing Check with the liner manufacturer to determine if insulation is required Insulation is recommended especially if the chimney is loca...

Page 8: ...s of the centerline of the insert See fig 6 A The convection chamber louvers of the zero clearance fireplace MUST NOT be blocked off The use of the cast iron surround panels may not be possible in the...

Page 9: ...gure 7 Mantel Clearance Detail measured from the hearth surface to the lowest mantel surface Clearance to Combustible Materials There may be no combustible materials located anywhere within 36 914 mm...

Page 10: ...or 8 stainless steel liner extending the full height of the chimney is required for those installations where the flue tile is greater than 8 x 12 for internal chimneys or 8 x 8 for external chimneys...

Page 11: ...ce Plate PN 220508 to the back wall of the masonry fireplace firebox where it will be readily seen should the insert be removed 3 3 3 3 3 If appropriate install the damper sealing plate according to t...

Page 12: ...rough the flex pipe at the three pilot hole locations in the adaptor and secure with sheet metal screws Installing the Fireplace Insert Power Cord Orientation 1 Determine to which side the blower powe...

Page 13: ...uir equired ed ed ed ed 10 mm socket or wrench 5 If appropriate attach the Extended Surround Panel to the firebox See illustration on page 6 With the painted side facing out engage the hooked tabs on...

Page 14: ...rting or reviving the fire the control lever should be set at the far right position to allow the maximum amount of air into the stove See fig 15 After the fire is well established the lever should be...

Page 15: ...y flue and connector pipe cleaned and inspected at the beginning of the heating season and then inspected twice per month during frequent use Clean the chimney whenever creosote accumu lation of 1 4 o...

Page 16: ...mperature and height all affect draft which in turn affects the formation of creosote An exterior chimney whether masonry or prefabricated steel will be exposed to cold outside temperatures and conseq...

Page 17: ...of by burial in soil or otherwise dispersed the the the the they should be k y should be k y should be k y should be k y should be kept ept ept ept ept in in in in in the the the the the closed c clos...

Page 18: ...liner and chimney can now be inspected and cleaned 9 See page 12 for reassembly procedures Gaskets Check door and glass gaskets for seal integrity The gaskets should be soft enough to be somewhat res...

Page 19: ...ngth Trim the gasket to leave 1 excess 3 Apply a small bead of gasket or furnace cement in the channel 4 Lightly press the new gasket into the channel being careful to avoid compressing or stretching...

Page 20: ...rica 55 Hutcherson Dr Gorham Maine 04038 Figure 20 J tul C 550 Rockland Illustrated Parts Diagram 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 12 23 24 25 28 27 26 29 30 12 31 32 33 34 35 36...

Page 21: ...ooden Knob Replacement Kit 151991 88 Handle Asy Complete Matte Black Paint 156320 Handle Asy Complete Nickel Plated 156021 89 Airwash Manifold inc gasket Matte Black Paint 156710 Airwash Manifold inc...

Page 22: ...alue of the proposed alternate floor protector a Use the formula in Step 1 to convert values not expressed as R b For multiple layers add R values of each layer to determine overall R value c If the o...

Page 23: ...156448 J tul C 550 Replacement Assemblies Front Plate Asy inc gasket Matte Black Paint 156482 Front Plate Asy inc gasket Blue Black Enamel 156483 Front Plate Asy inc gasket J tul Iron Paint 156484 Fr...

Page 24: ...lations It is important that the these instructions be carefully read and understood before beginning the installation J tul pursues a policy of continual product development Consequently products may...

Reviews: