9
ADDITIONAL OPTIONS (2/2)
VOLTAGE SWITCH
The TEC-44 can be converted to suit 115VAC or 230VAC electrical systems. Use the below
mentioned diagrams to configure your drain to the corresponding electrical power supply.
1 2 3 4
5 6 7 8
1 2 3 4
5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Place jumpers on points 1&2
and 3&4.
L N
L N
Place both jumpers on points 2&3.
230VAC
115VAC