SAFETY AND PROPER USAGE

 

To ensure safe and enduring performance of this product, you must comply strictly with the instructions enclosed 
herein. Non-compliance with instructions or improper handling of the product will void your warranty! Usage of 
this product in conditions not specified in this manual or in contrary to the instructions hereby provided is 
considered IMPROPER. The manufacturer will not be held liable for any damages resulting from improper use of 
the product. 

SAFETY & WARNING INSTRUCTIONS

 

- Observe valid and generally accepted safety rules when planning, installing and using this product. 
- Take proper measures to prevent unintentional operation of the product or damage to it. 
- Do not attempt to disassemble this product or lines in the system while they are under pressure. 
- Always depressurise the compressed air system before working on the system. 

It is important that personnel use safe working practices and observe all regulations and legal requirements for 
safety when  operating this product. When handling, operating or carrying out maintenance on this product, 
personnel must employ safe engineering practices and observe all local health & safety requirements & 
regulations. International users refer to regulations that prevail within the country of installation. Most accidents, 
which occur during the  operation and maintenance of machinery, are the result of failure to observe basic safety 
rules or precautions. An accident can often be avoided by recognising a situation that is potentially dangerous. 
Improper operation or maintenance of this product could be dangerous and result in an accident causing injury or 
death. The manufacturer cannot anticipate every possible circumstance, which may represent a potential hazard.  
The WARNINGS in this manual cover the most common potential hazards and are therefore not all-inclusive. If 
the user employs an operating procedure, an item of equipment or a method of working which is not specifically 
recommended by the manufacturer he must ensure that the product will not be damaged or made unsafe and 
that there is no risk to persons or property.   

Summary of Contents for TEC-44

Page 1: ...1 Installation instructions 10 2015 ...

Page 2: ...d legal requirements for safety when operating this product When handling operating or carrying out maintenance on this product personnel must employ safe engineering practices and observe all local health safety requirements regulations International users refer to regulations that prevail within the country of installation Most accidents which occur during the operation and maintenance of machin...

Page 3: ...6 CHANGING THE INTERVAL TIME CYCLE Should the pre set interval time cycle 4 not be suitable for your requirements alternative interval times can be selected Refer to chart 1 page 6 and select the program best suited to your requirements Follow the procedure below to change the program a Choose the preferred program 0 9 or b Press SET until your program number is displayed 7 CHANGING THE ROTATION T...

Page 4: ...4 1 2 3 4 5 6 7 8 9 ...

Page 5: ...5 Housing screw plug 4 Housing top part with attached cable Motor Valve indicator Washer 2 Housing screw 4 Gasket Housing bottom part Ball valve Bolt 2 ...

Page 6: ...nds rotation valve stays open 13 s 4 1 hrs E 25 seconds rotation valve stays open 18 s 5 2 hrs F 30 seconds rotation valve stays open 23 s 6 4 hrs H 45 seconds rotation valve stays open 38 s 7 8 hrs L 1 minute rotation valve stays open 53 s 8 16 hrs P 5 minutes rotation valve stays open 4m 53 s 9 24 hrs o 15 minutes rotation valve stays open 14m 53 s External Switching see page 8 adding a remote s...

Page 7: ...re The Power Failure Protection Safeguard consists of 4 AA size 1 5V penlight batteries 1 To re place the batteries open the housing by unscrewing the 4 housing screws 2 Place the 4 batteries and close the housing by replacing the 4 housing screws Rely as little as possible on the power failure protection safeguard Solve the power supply problem as soon as possible ...

Page 8: ...8 ADDITIONAL OPTIONS 1 2 REMOTE SWITCHING The TEC 44 can be controlled by a remote switch See illustration below how to connect a remote control 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 L N Remote switch ...

Page 9: ...or 230VAC electrical systems Use the below mentioned diagrams to configure your drain to the corresponding electrical power supply 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Place jumpers on points 1 2 and 3 4 L N L N Place both jumpers on points 2 3 230VAC 115VAC ...

Page 10: ...r pcb SMT technology ensuring consistency in production Timer cycle indication Bright LED illumination LED program indicator Test feature Yes Valve type 2 2 way motorised ball valve Valve orifice 12 mm 0 5 Valve seals FPM and Teflon Inlet outlet connections 1 2 BSP or NPT Inlet connection height 1 0 cm 0 04 Serviceable valve Yes Valve housing material Brass nickel plated Stainless steel available ...

Page 11: ...11 SERVICE CHART Date Description Name ...

Page 12: ...12 DIMENSIONS mm ...

Reviews: