background image

 

 
SAFETY AND PROPER USAGE

 

To ensure safe and enduring performance of this product, you must comply strictly with the instructions enclosed 
herein. Non-compliance with instructions or improper handling of the product will void your warranty! Usage of 
this product in conditions not specified in this manual or in contrary to the instructions hereby provided is 
considered IMPROPER. The manufacturer will not be held liable for any damages resulting from improper use of 
the product.

 

SAFETY & WARNING INSTRUCTIONS

 

- Observe valid and generally accepted safety rules when planning, installing and using this product. 
- Take proper measures to prevent unintentional operation of the product or damage to it. 
- Do not attempt to disassemble this product or lines in the system while they are under pressure. 
- Always depressurise the compressed air system before working on the system. 

 

 
It is important that personnel use safe working practices and observe all regulations and legal requirements for 
safety when  operating this product. When handling, operating or carrying out maintenance on this product, 
personnel must employ safe engineering practices and observe all local health & safety requirements & regulations. 
International users refer to regulations that prevail within the country of installation. Most accidents, which occur 
during the  operation and maintenance of machinery, are the result of failure to observe basic safety rules or 
precautions. An accident can often be avoided by recognising a situation that is potentially dangerous. Improper 
operation or maintenance of this product could be dangerous and result in an accident causing injury or death. The 
manufacturer cannot anticipate every possible circumstance, which may represent a potential hazard. The 
WARNINGS in this manual cover the most common potential hazards and are therefore not all-inclusive. If the user 
employs an operating procedure, an item of equipment or a method of working which is not specifically 
recommended by the manufacturer he must ensure that the product will not be damaged or made unsafe and that 
there is no risk to persons or property.   
 

NEVER CHANGE ORIGINAL COMPONENTS WITH ALTERNATIVES

 

Summary of Contents for FLUIDRAIN-COMBO-QUICKSET

Page 1: ...1 INSTALLATION MAINTENANCE INSTRUCTIONS 12 2017...

Page 2: ...afety when operating this product When handling operating or carrying out maintenance on this product personnel must employ safe engineering practices and observe all local health safety requirements...

Page 3: ...you can mount the timer up right or upside down 1 6 Remove the protection cap from the connector and connect your power cable to the connector as illustrated Close the connector and tighten the botto...

Page 4: ...4 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 1 10 1 11...

Page 5: ...5 Timer gasket Quick Set Timer Connector gasket Connector Screw Top nut Gasket Coil Valve Shaft Gasket Small spring Large spring Plunger Valve body...

Page 6: ...coil assembly from the valve shaft 2 6 Unscrew the valve shaft using a 23mm wrench Do not use the valve shaft as a lever 2 7 Clean all the valve parts Note if any parts are damaged please replace them...

Page 7: ...7 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 2 10 2 11 2 12...

Page 8: ...perature 1 55 C 34 131 F Timer range Pressure Capacity 5 10 bar 0 5 20 m min Timer PCB SMD technology Timer cycle indication LED Test feature Yes Valve type 2 2 way direct acting Valve orifice 4 mm Va...

Page 9: ...9 SERVICE CHART Date Description Name...

Page 10: ...10 DIMENSIONS mm...

Page 11: ...eep the first wrench in place Do not use the Valve Shaft as lever Proper installation Screw in a hose barb adapter Use a wrench to lock the valve Use a second wrench to install the hose barb adapter U...