INSTALLATION INSTRUCTIONS

 

 

Before installing this product, make sure it complies with your request and that it suits your application!

 

1.1 Unpack the unit and visually inspect for any transport damage incurred after leaving our factory. 
1.2 Depressurise the system before installation or maintenance is carried out! 
1.3 Locate a suitable condensate draining point on your compressed air system and connect your valve using a 22mm 
wrench. Connect the outlet to an oil/water separator.  
- Make sure the arrow on the valve body complies with the flow direction of the condensate.  
- Do not use the valve shaft as lever!
 
1.4 Slide the coil on to the valve shaft and screw on the top nut. Make sure the gaskets are placed properly to ensure 
IP65 rating. Place the timer gasket over the coil connection pins.  
Make sure there is no debris between the gasket and the coil. 
1.5 Mount the timer on to the coil as illustrated, you can mount the timer up-right or upside-down. 
1.6 Remove the protection cap from the connector and connect your power cable to the connector as illustrated. 
Close the connector and tighten the bottom nut firmly. 
1.7 Place the connector gasket on the connector, place the connector on the timer as illustrated and tighten  
the screw (max. torque 1Nm). Make sure both gaskets are secured properly to ensure IP65 rating. 
1.8 After double checking that the power supply corresponds with the voltage specified on the coil and falls within the 
range specified on the back of the timer, you can switch the power supply ON. 
1.9 Slowly open the ball valve to restore normal system pressure. 
1.10 Press the TEST button to check the valve function. Adjust the PRESSURE and CAPACITY buttons to suit your system. 
1.11 Your drain is ready for operation! 
Note: We advise to check this product at least once a year and replace serviceable parts when necessary. 
Note: Clean the strainer periodically to avoid possible blocking causes by rust and/or debris. 
Note: Check the valve function periodically. A purging sound must be heard.  
 

Summary of Contents for FLUIDRAIN-COMBO-QUICKSET

Page 1: ...1 INSTALLATION MAINTENANCE INSTRUCTIONS 12 2017...

Page 2: ...afety when operating this product When handling operating or carrying out maintenance on this product personnel must employ safe engineering practices and observe all local health safety requirements...

Page 3: ...you can mount the timer up right or upside down 1 6 Remove the protection cap from the connector and connect your power cable to the connector as illustrated Close the connector and tighten the botto...

Page 4: ...4 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 1 10 1 11...

Page 5: ...5 Timer gasket Quick Set Timer Connector gasket Connector Screw Top nut Gasket Coil Valve Shaft Gasket Small spring Large spring Plunger Valve body...

Page 6: ...coil assembly from the valve shaft 2 6 Unscrew the valve shaft using a 23mm wrench Do not use the valve shaft as a lever 2 7 Clean all the valve parts Note if any parts are damaged please replace them...

Page 7: ...7 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 2 10 2 11 2 12...

Page 8: ...perature 1 55 C 34 131 F Timer range Pressure Capacity 5 10 bar 0 5 20 m min Timer PCB SMD technology Timer cycle indication LED Test feature Yes Valve type 2 2 way direct acting Valve orifice 4 mm Va...

Page 9: ...9 SERVICE CHART Date Description Name...

Page 10: ...10 DIMENSIONS mm...

Page 11: ...eep the first wrench in place Do not use the Valve Shaft as lever Proper installation Screw in a hose barb adapter Use a wrench to lock the valve Use a second wrench to install the hose barb adapter U...

Reviews: