background image

Safety, Operation and Maintenance Manual 

with Parts List

Please read before use!

100 PSI

Important Information and Safety Instructions

Register your Machine at www.jondon.com

Serial No:                                                         

© 2015 Copy Rights Reserved Jon-Don, Inc.

Prospector PE100 Extra

ctor

REGISTER 

YOUR 

MACHINE 

ONLINE!

Reliable Power

Innovative Design

Safe & Easy to Use

Powerful Extracting

Easy Transport

Patented Features

Model No. PE100

Summary of Contents for Prospector PE100

Page 1: ...InformationandSafetyInstructions Register your Machine at www jondon com Serial No 2015 Copy Rights Reserved Jon Don Inc Prospector PE100 Extractor REGISTER YOUR MACHINE ONLINE Reliable Power Innovati...

Page 2: ...uipment defective or not This warranty is in lieu of all expressed or implied warranties and is extended only to the original retail purchaser Manufacturer sales and service representatives are not au...

Page 3: ...NOT use if cord or plug are damaged Keep cord away from heated surfaces DO NOT use outdoors in standing water on wet surfaces DO NOT pick up flammable or combustible materials or use machine where the...

Page 4: ...ion tank the solution pump must be primed Connect the short prime hose that was included with your machine to the solution outlet quick connect and place the open end of priming hose inside the vacuum...

Page 5: ...en finished cleaning turn OFF all switches If the auto fill system was used and there is still water in the solution tank push the float down to release the water inlet hose pressure before disconnect...

Page 6: ...ter from being sucked into the vacuum motors Operating the Prospector Carpet Extractor without the float assembly or with a poorly maintained assembly will greatly decrease the life of the vacuum moto...

Page 7: ...machine s lines and pump Failure to do so may clog your lines and pump Every two weeks pour vinegar into the solution tank dilute with 1 2 water Run the pump while squeezing your wand or upholstery to...

Page 8: ...and connect the solution hose to the male QD at the auto fill chemical feed connection CAUTION applying high pressure over 100 PSI to the chemical feed system will damage the mechanism With the chemi...

Page 9: ...ectrical System Unit will not Turn On 1 Extension Cord not Plugged In 2 Switch not in the On Position 3 Building Circuit Overloaded 4 Wiring Connections Loose 1 Check if Machine and Cord are Plugged I...

Page 10: ...9 Prospector 100 PSI Carpet Extractor 8 0 Machine Schematic Drawing...

Page 11: ...BS Street Elbow 3 00 28 10 0833 Motor Manifold Bolts for Extractor 10 00 29 10 0204 Motor Mount Back Up Washer 18 00 30 10 0811 2 Stage Extractor Motor 2 00 31 10 0838 A Complete Pigtail for Extractor...

Page 12: ...It is the responsibility of the distributor to repair the client s equipment as soon as possible Labor is only provided by authorized service centers If an authorized service center is not near you i...

Reviews: