(6) Prospector 100 PSI Carpet Extractor
5.4 Clean Pump Inlet Filter
CAUTION: before proceeding with this procedure, make sure both the power cords are disconnected.
• To examine the filter, open the solution tank lid on the front of the machine. The filter is in the bottom of the solution
tank.
• Grasp the filter cap and unscrew the filter from the brass nipple by turning counter-clockwise. Clean or replace the
filter as needed.
To prevent moisture from damaging the vacuum motors during storage, empty the recovery tank and store with the lid
open.
5.4 Prevent Mineral Deposit Build-Up
Vinegar may be used to prevent mineral deposit build-up in your machine’s lines and pump. Failure to do so may clog
your lines and pump. Every two weeks, pour vinegar into the solution tank (dilute with 1/2 water). Run the pump, while
squeezing your wand or upholstery tool’s trigger unit you smell vinegar or notice it coming out of the tool. Let the
machine sit overnight, and no longer, with the vinegar in its lines. The next day, flush the machine with 1-gallon of clean
water or until you do not smell vinegar any longer.
PLEASE NOTE: If you choose to use CLR, follow the directions on the bottle. DO NOT leave CLR in the machine’s
lines and flush thoroughly. CLR may corrode the machine’s components and VOID your warranty. If you choose to use
vinegar, MUST dilute with 1/2 water. Failure to do so may damage the machine’s components and VOID your warranty.
1/4” Acorn Strainer
Part No. 10-0845
Solution Tank
Latch
Base