APPLIANCE START AND USE
After professionally installing the room ventilation system, the fume exhaust system and electrical system according to the relevant
regulations, the specialised Technical Service Center can provide the optional Commissioning service.
Follow these steps to start using the product: load pellet of the recommended quality in the tank, set the desired temperature and heat
output level (we recommend setting level 3) and press Button 3 to turn on the device.
Whilst operating, with the WORK message on the control unit display, the device has a heating output according to one of the 5 levels
of output set. The device remains in operating mode; i.e. at the heat output level, until the set ambient temperature is exceeded by 0.5
°C. At this point it will switch to the ECO mode function. The device will switch back to WORK mode when the ambient temperature
decreases 1.0°C below the SET ambient temperature.
When operating in WORK mode, the fan speed for the hot air exhausted through the grid depends on the output levels; the higher the
output level, the faster the air will be pumped through the front grid.
With STAND-BY, MENU 5 mode enabled, it is possible to switch off the device if the ambient temperature conditions are satisfied within
the values set for the OFF Delta temperature value. The OFF Delta, is the temperature differential between the SET ambient temperature
and the actual ambient temperature. Therefore if, for instance, the SET ambient temperature is 19°C, with an OFF Delta of 2°C and a
switch-off delay of 5’, when the ambient temperature remains above 21°C for at least 5 minutes, the device will switch off. The device
will remain in STD-BY until the ambient temperature reaches 1°C of the SET ambient temperature which correspond to the automatic
start-up value of the stove. In this condition, the stove is not actually off but is waiting to turn back on if the above conditions are satisfied.
Set SET CHRONO – MENU 2 to time operation start and stop. The crono can be quickly started by pressing Button 6 on the main display
screen. CHRONO and STAND-BY modes cannot be activated simultaneously. The CHRONO function should be considered as a timer
function, while STAND-BY is a temperature function.
In the event of alarms and/or manual pellet load from MENU 7, message CLEAN BASKET is a warning to be sure not to turn on the stove
with excessive pellets in the brazier. To cancel the message, clean the brazier and press and hold down Button 3 for three seconds.
Loading must be performed if the auger is empty, after a NO PELLET alarm, or after maintenance or cleaning of the container. Every
time the manual pellet load mode is enabled, the firebox MUST be emptied to create the correct conditions for the stove start-up phase.
The device can be switched off while operating with manual intervention by the user or by setting a SET-TIMER or can switch off if an
alarm is triggered following a device malfunction.
In the second case follow the indications provided in CHAP. 09 - FAULT DIAGNOSIS AND TROUBLESHOOTING.
T
he installation technician must attend the optional Commissioning service since system components may require
adjustments not pertinent to the specialised Technical Service Center at this time.
Any additional work or intervention of the specialised Technicat Service Center due to the failure to complete the above
adjustments during the optional Commitioning service are at the user’s expense.
WARNING
The device must only be used with the combustion chamber door closed.
The pellet hatch must be closed while the machine is running.
The stove starting MUST ALWAYS be performed with clean and empty firebox.