14
All appliance tests, final inspection and fine-tuning was performed using the recommended certified pellets.. Jolly
Mec Caminetti S.p.A. is not responsible for malfunctions, breakdowns or problems due to the use of pellets that are not
recommended, as combustion parameters vary according to the quality of the pellets.
To achieve best operational results, it may be necessary to change the default factory settings on the control unit during
the optional Commissioning service. These operations must only be performed by a specialised Technical Service Center.
WARNING
CHAP.06 TECHNICAL DATA
06.1 HOMOLOGATION
Technical specifications resulting from laboratory tests conducted according to EN 14785:2006 test methods at the CERTIFICATION
institute.
Description
AMBRIA2 6 kW AMBRIA2 8 kW UM
Nominal burning output
6,9
9,0
kW
Nominal heat output
6,4
8,2
kW
Reduced heat output
2,4
2,4
kW
Nominal output consumption
1,432
1,870
Kg/h
Reduced output consumption
0,53
0,53
Kg/h
Nominal output efficiency
92,0
90,6
%
Rated voltage
230
230
V
Rated frequency
50
50
Hz
Electrical absorption (Switching on - nominal power - reduced power - stand-by)
310 - 60 - 15 - 2,2 310 - 65 - 15 - 2,2 W
Device mass
110
110
Kg
Standard hopper capacity
15
15
Kg
Flue draught (Nominal heat output- Reduced heat output)
10,0 - 8,0
10,0 - 8,0
Pa
Fume exhaust diam.
80
80
mm
Average fume Temperature at nominal output
134,7
167,8
°C
Average fume Temperature at reduced output
91,3
91,3
°C
CO (13% O
2
) at nominal output
61
113
mg/m
3
CO (13% O
2
) at reduced output
461
461
mg/m
3
CO
2
at nominal output
11,22
12,52
%
NOx (13% O
2
) at nominal output
158
139
mg/m
3
OGC (13% O
2
) at nominal output
2
3
mg/m
3
Polveri (13% O
2
) at nominal output
20
20
mg/m
3
Nominal fume mass output
4,4
5,2
g/s
Reduced fume mass output
2,5
2,5
g/s
Average heated area*
43 - 67,7
55,2 - 86,7
m
2
Minimum air distance from inflammable side wall
200
400
mm
Minimum air distance from inflammable rear wall
100
100
mm
Frontal air distance from inflammable material
900
900
mm
Comburent air pipe diameter
50
50
mm
Energy efficiency class
A+
A+
-
The declared output may vary according to fuel type.
The above technical specifications were measured with certified quality PELLETS. ONLY use this type of fuel as recommended later in
CHAP.06.2 - RECOMMENDED FUELS.
*According to the typology of building and insulation (Referred to the need of 55 W/m
3
and 35 W/m
3
; room height 2,7 m).
Summary of Contents for AMBRIA2
Page 34: ...34 NOTES...
Page 35: ...35 ENGLISH NOTES...