Typical applications
Bilge pump, fresh water pump, deck
washing, fuel oil transfer, fire pump,
etc.
design features
Body:
Bronze
Impeller:
NBR rubber
Seal:
Lip seal, NBR rubber
O-ring:
NBR rubber
Connection: 1/" Internal BSP/NPT
or 1" hose (ø 5 mm)
Liquid
temperature: Max +80°C
Motor:
0,5 kW, 1/4 V DC
with built in thermal
protection
Total enclosed
Reversible
Shaft:
Stainless Steel
Bearings: Permanent
lubricated,
sealed,
ball bearings
The motor is ignition protected accor-
ding to ISO 8846 (Small craft - Electri-
cal devices - Protection against ignition
of surrounding flammable gases).
Pressure and capacity data
(based on water at 0°C and at full
voltage of the motor)
Ampere draw
Bar kPa l/min USGPM
12 V 24 V
cont. duty
0
0
48
1,7
1, A 6,5 A
0,1
10
45
11,9
1,3 A 6,7 A
0,3
30
41
10,8
13,1 A 7,1 A
0,6
60
34
9,0
14,9 A 7,5 A
Intermittent duty
0,9
90
5
6,6
16,5 A 7,8 A
1, 10
11
,9
18,3 A 8,8 A
Fuse required
25 A 15 A
Self-priming, flexible impeller pump flange mounted to
dc motorn 12/24 V
Type designation
Type
Part No
F4B-19 (BSP)
1 V 10-4689-01
F4B-19 (BSP)
4 V 10-4689-0
F4B-1907 (NPTF) 1V 10-4689-03
F4B-1907 (NPTF) 4V 10-4689-04
Installation and maintenance
Installation
Pump may be mounted in any position
without loss of efficiency; however, it is
suggested that the pump head be down
if vertical mounting is desired. Mount
motor as close as possible to power source
to obtain full voltage.
The pump should be installed so that
the motor is protected from rain or
wash down.
When using a vac-on-switch, mount
it on the connection on the inlet side
of the pump. When using a pressure
switch, mount it on the outlet side of
the pump.
electrical installation
The pump must be installed according to
ISO 10133 (Small craft - Electrical system
- Extra low voltage DC installation for
continuous current). Note: The fuse must
be ignition protected.
The motor is equipped with built in
thermal protection to prevent the mo-
tor from overheating. The protection is
automatically restored when the motor
is cooled.
If the pump is connected with separate
earth lead, this should be yellow/green
and connected to the motor base.
See the wiring table (next page) for
correct installation. Negative wire must
be black.
Choose wire size in accordance with total
wire lenght (see table next page).
The wire connections must be sealed with
a marine sealant.