8. Replace the Schrader core in the liquid and vapor valves.
9. Leak test all refrigerant piping connections including the service port
flare caps to be sure they are leak tight. DO NOT OVERTIGHTEN
(between 40 and 60 inch - lbs. maximum).
10. Evacuate the vapor line, evaporator, and liquid line to 500 microns
or less.
11. Replace cap on service ports. Do not remove the flare caps from the
service ports except when necessary for servicing the system.
12. Release the refrigerant charge into the system. Open both the liquid
and vapor valves by removing the service valve cap and with an
Allen wrench back out counter-clockwise until valve stem just
touches the chamfered retaining wall. If the service valve is a ball
valve, use a Crescent wrench to turn valve stem one-quarter turn
counterclockwise to open. Do not overturn or the valve stem may
break or become damaged. See “PRECAUTIONS DURING BRAZ-
ING SERVICE VALVE”.
13. Replace service valve cap finger tight, then tighten an additional 1/2
turn (1/2 hex flat). Cap must be replaced to prevent leaks.
14. See
Section VI “System Charge” section for checking and recording
system charge.
SECTION IV: EVACUATION
Evacuate the system to 500 microns or less. If a leak is suspected, leak
test with dry nitrogen to locate the leak. Repair the leak and test again.
To verify that the system has no leaks, simply close the valve to the
vacuum pump suction to isolate the pump and hold the system under
vacuum. Watch the micron gauge for a few minutes. If the micron
gauge indicates a steady and continuous rise, it’s an indication of a
leak. If the gauge shows a rise, then levels off after a few minutes and
remains fairly constant, it’s an indication that the system is leak free but
still contains moisture and may require further evacuation if the reading
is above 500 microns.
SECTION V: ELECTRICAL CONNECTIONS
GENERAL INFORMATION & GROUNDING
The control box cover is held in place with 5 screws (one screw near
each lower corner, one each at the midpoint of each side and one at top
middle).
Check the electrical supply to be sure that it meets the values specified
on the unit nameplate and wiring label.
Power wiring, control (low voltage) wiring, disconnect switches and over
current protection must be supplied by the installer. Wire size should be
sized per NEC requirements.
The complete connection diagram and schematic wiring label is located
on the inside surface of the unit service access panel. An example of
typical field connections can be found in Figure 7.
FIELD CONNECTIONS POWER WIRING
1. Install the proper size weatherproof disconnect switch outdoors and
within sight of the unit, per local code.
2. Remove the screws at the top and sides of the corner cover. Slide
the control box cover down and remove from unit.
3. Run power wiring from the disconnect switch to the unit.
4. Route wires from disconnect through power wiring exit provided and
into the unit control box as shown in Figure 1 and view the openings
in Figure 6.
5. Make the power supply connections to the supplied terminal block.
FIELD CONNECTIONS CONTROL WIRING
1. Route low voltage wiring into bottom of control box through the hole
inside the low voltage box. Connect low voltage wiring inside the low
voltage box by clipping and discarding the connector plug and strip-
ping the low voltage wires. See Figure 6.
2. The complete connection diagram and schematic wiring label is
located on the inside surface of the unit service access panel.
3. Replace the control box cover removed in Step 2 of the FIELD
CONNECTIONS POWER WIRING procedures.
4. All field wiring to be in accordance with national electrical codes
(NEC) and/or local-city codes.
5. Mount the thermostat about 5 ft. above the floor, where it will be
exposed to normal room air circulation. Do not place it on an outside
wall or where it is exposed to the radiant effect from exposed glass
or appliances, drafts from outside doors or supply air grilles.
6. Route the 24-volt control wiring (NEC Class 2) from the outdoor unit
to the indoor unit and thermostat. Keep the low voltage wiring 4" or
more away from the high voltage wires that are leaving the control
box. If this isn't possible, install shielded low voltage wiring to
reduce EMI risk.
NOTICE
Line set and indoor coil can be pressurized to 250 psig with dry nitro-
gen and leak tested with a bubble type leak detector. Then release
the nitrogen charge.
Do not use the system refrigerant in the outdoor unit to purge or leak
test.
CAUTION
Do not connect manifold gauges unless trouble is suspected. Approx-
imately 3/4 ounce of refrigerant will be lost each time a standard man-
ifold gauge is connected.
WARNING
Never attempt to repair any brazed connections while the system is
under pressure. Personal injury could result.
CAUTION
All field wiring must USE COPPER CONDUCTORS ONLY and be in
accordance with Local, National, Fire, Safety & Electrical Codes. This
unit must be grounded with a separate ground wire in accordance
with the above codes.
!
!
!
FIGURE 6:
Outdoor Unit Control Box
OUTDOOR
D
I
SP
L
A
Y
A
0770-001
ACCESS
PA
N
E
L
S
WI
TCH
OUTDOOR
REACTOR
/
CHO
K
E
OUTDOOR
FIL
TER
CO
N
TRO
LL
ER
(
Ma
y
not
b
e
used
on
a
ll
units
)
L
O
W
VO
L
TA
G
E
FI
E
L
D
WI
R
ING B
O
X
AM
BI
E
N
T
TEMPERATURE
SE
N
SOR
H
IG
H
VO
L
TA
G
E
FI
E
L
D
WI
R
ING
H
IG
H
VO
L
TA
G
E
CO
N
DU
I
T P
L
ATE
G
ROU
N
D
L
U
G
FI
E
L
D
WI
R
ING
TERM
IN
A
L
BL
OC
K
IN
VERTER
DR
I
VE
TRA
N
S
F
ORMER
MA
IN
CO
N
TRO
L
B
OARD
DO NOT
connect
the
“
R
”
ter
m
ina
l
o
f
unit
contro
l b
oard
.