VRF Air-Conditioner IOM

 

 

 
 
 
 

Model 

YDEC028 

YDEC036 

YDEC045 

YDEC056 

YDEC071 

Cooling Capacity 

kW 

2.8 

3.6 

4.5 

5.6 

7.1 

Heating Capacity 

kW 

3.2 

4.0 

5.0 

6.3 

8.0 

Power supply 

220V ~ 50Hz 

Rated Power 

110 

110 

130 

130 

180 

Rated Current 

0.55 

0.55 

0.65 

0.65 

0.83 

Air Flow Rate 

m

3

/h 

600 

600 

950 

950 

1250 

External Static Pressure 

Pa 

Dimension 

HxWxD 

mm 

680x1245x240  680x1245x240  680x1245x240  680x1245x240  680x1245x240 

Connecting Pipes 

Liquid/Gas  (φ)mm 

6.35/9.52 

6.35/12.7 

6.35/12.7 

6.35/12.7 

9.52/15.88 

Drainage Pipe 

(φ)mm 

16(O.D.) 

Model 

YDEC080 

YDEC090 

YDEC112 

YDEC140 

YDEC160 

Cooling Capacity 

kW 

8.0 

9.0 

11.2 

14.0 

16.0 

Heating Capacity 

kW 

9.0 

10.0 

12.5 

16.0 

18.0 

Power supply 

220V ~ 50Hz 

Rated Power 

210 

210 

210 

250 

250 

Rated Current 

0.97 

0.97 

0.97 

1.20 

1.20 

Air Flow Rate 

m

3

/h 

1550 

1550 

1550 

1950 

1950 

External Static Pressure 

Pa 

Dimension 

HxWxD 

mm 

680x1245x240  680x1245x240  680x1670x240  680x1670x240  680x1670x240 

Connecting Pipes 

Liquid/Gas  (φ)mm 

9.52/15.88 

9.52/15.88 

9.52/15.88 

9.52/15.88 

9.52/15.88 

Drainage Pipe 

(φ)mm 

16(O.D.) 

 

 
 
 
 
 

 

 
 
 
 

Summary of Contents for York YDEC028

Page 1: ...VRF Air Conditioner Installation Manual FORM NO YDEC IOM EN 1212 ...

Page 2: ...cting Pipes Liquid Gas φ mm 6 35 9 52 6 35 12 7 6 35 12 7 6 35 12 7 9 52 15 88 Drainage Pipe φ mm 16 O D Model YDEC080 YDEC090 YDEC112 YDEC140 YDEC160 Cooling Capacity kW 8 0 9 0 11 2 14 0 16 0 Heating Capacity kW 9 0 10 0 12 5 16 0 18 0 Power supply 220V 50Hz Rated Power W 210 210 210 250 250 Rated Current A 0 97 0 97 0 97 1 20 1 20 Air Flow Rate m3 h 1550 1550 1550 1950 1950 External Static Pres...

Page 3: ... Contents 1 SAFETY CAUTIONS 1 2 BEFORE INSTALLATION 1 3 SELECTION OF INSTALLATION POSITION 2 4 INSTALLATION OF INDOOR UNIT 2 5 INSTALLATION OF REFRIGERANT PIPING 4 6 INSTALLATION OF DRAINAGE PIPING 5 7 ELECTRIC CONNECTION 6 ...

Page 4: ...ge earthing breaker is not installed there will be electric shock hazard or fire hazard Please arrange drainage piping according to this instruction to guarantee smooth drainage and insulate the piping in case of condensed water accumulation Improper piping may lead to water leakage and soak household items Air conditioner power line and connecting line shall be far away from more than 1m at least...

Page 5: ...nd the superhard walls as much as possible in holing the hole inside shall be 0 5cm 1cm higher than outside considering drainage wall hole passing through outlet pipe of indoor unit side shall be slightly lower than the indoor unit downside for holing with diamond plastic cloth shall be sticked to wall or other method may be adopted to prevent water flow to wall for holing with electric hammer dus...

Page 6: ... must be opened on the ceiling before installation with the specification as follows 1170 610 for 028 112 type and 1600 610 for 140 160 type take down the right and left cover plates of indoor unit and then embed one half of main body into the ceiling and only expose rear cover plate and head cover For seat installation use gradienter to install Hoisting bolt Hoisting bolt Hoisting support Hoistin...

Page 7: ... designated refrigerant anything for example air shall not mix into refrigerating circuit Before welding refrigerant piping please conduct nitrogen replacement or fill nitrogen into piping in welding and finally connect with indoor unit by horn mouth When filling nitrogen into piping in welding guarantee to control the pressure with reducing valve as 0 02MPa 0 2kgf cm2 like the feel of breeze blow...

Page 8: ... good thermal insulation Field piping must be connected to the piping connecting part all the time If poor thermal insulation for piping there will be dew outside and scald if any touch 6 Installation of Drainage Piping 6 1 Drainage piping installation In delivery the drainage outlet is PVC pipe in connecting water pipe please use auxiliary sealing material and sleeve Conduct thermal insulation fo...

Page 9: ...ional electrician Line breaker or leakage breaker must be arranged at power supply Earthing resistance must below 4Ω Air conditioner must be earthed reliably Earthing wire shall not be connected to gas pipe tap water pipe lightening rod or telephone line Do not power on before the end of all the electric operation The terminal of the same power supply shall not be connected with two wires with dif...

Page 10: ...on wire of TB3 outlet connects to the communication port of the next indoor unit TB2 inlet Inlet and outlet lines TB2 inlet and TB3 outlet of indoor unit shall not be reversed otherwise there will be fault and the unit can t be started Connect according to the diagram do not allow A and B polarity connection error otherwise communication failure or controller damage may be caused In order to avoid...

Page 11: ...roller can connect to max 4 indoor units The indoor units in one group should be connected in one and same power supply to guarantee normal initialization of wire controller when power on Connection sketch of indoor unit and wire controller a When one wire controller connecting only one indoor unit refer to Fig 13 b When one wire controller connecting multi indoor units refer to Fig 14 Fig 13 One ...

Page 12: ...9 YDEC IOM EN 1212 NONE YDEC IOM 0812 ...

Reviews: