Section 5: Programming
Note:
If entry delay is active at auto-disarm time, the system does not disarm. A valid disarming procedure is required by the
user who initiated the entry delay.
[003] – Partition Auto-Disarming Holiday Schedules
Use this section to select a holiday schedule group.
See "[711]-[714] Holiday Schedules" on page 132for more information.
[004] – Partition Auto-Arming Pre-Alert Timer
Use this section to program the duration of the auto-arm pre-alert. The system arms when the pre-alert timer expires. Valid
entries are from 001 - 255 minutes.
If a valid access code is keyed in, this timer is postponed for the length of time programmed in Partition Auto-Arm Postpone
timer (see below). The pre-alert timer can be postponed multiple times. Keyswitches and proximity tags can be used to can-
cel auto-arming.
[005] – Partition Auto-Arm Postpone Timer
Use this section to program the length of time the auto-arm pre-alert timer is postponed for. Valid entries are between 001
and 255 minutes. 000 cancels the postpone timer.
When the postpone timer expires, the Auto-arm pre-alert timer restarts (unless the partition is armed). If left uninterrupted the
partition arms at the end of the pre-alert.
If a code is entered during the pre-alert, auto-arm cancel/postpone is logged and communicated and the postpone timer
starts. When the postpone timer expires, pre-alert is sounded again and the cycle repeats. The Auto-arm may be postponed
multiple times.
[006] – Partition No Activity Arming Timer
Use this section to program the duration of the No Activity timer. If this timer expires and no zones have been activated, the
partition arms in Away mode (exit delay will not sound). When the timer expires, keypad buzzers activate for the time pro-
grammed in No Activity Arming Pre-Alert (see below).
The timer restarts when a delay type zone is restored. The timer does not restart when the system is disarmed. The timer
stops if an un-bypassed zone is tripped, tampered or restored or with any keypad activity.
Separate No Activity Arming timers are provided for each partition.
Valid entries are from 000 – 255 minutes. 000 disables this feature.
[007] – Partition No Activity Arming Pre-Alert Timer
Use this section to program the duration of the No Activity Arming pre-alert that sounds when the No-Activity timer for the par-
tition expires. If any key is pressed or zone is activated or restored, the No Activity Arming pre-alert is aborted.
Valid entries are 000 - 255 minutes. 000 disables this feature.
Note :
Wireless key arm keys cannot be used to cancel no activity pre-alert.
[200] Partition Mask
A partition is a limited area of the premises which operates independently from the other areas. Partitions are added or
removed from the system by applying or removing a partition mask.
[001] – Partition 1 to 8 Enable Mask
Select options 01-08 to enable or disable partitions.
Partition 1 is always enabled. Partitions 2 to 8 are selectable.
The number of available partitions depends on the model, as shown below:
Model
Zones
Partitions
HS3032
32
4
HS3128
128
8
HS3248
248
8