FIRECLASS Fire detection system
Note FC-FI Switches and Jumper Positions
Installation Guide
Doc. version 2.0
25
10.5 Note FC-FI Switches and
Jumper Positions
The FC-FI board has many connectors, jumpers and
configuration switches. These are used, for example,
when diagnosing problems and when configuring the
board for additional modules. It is outside the scope of
this installation guide to provide details of these, and the
factory settings will be applicable in most situations.
Where necessary details will be found in other guides,
such as installation leaflets.
10.6 Make Jumper and DIP Switch
Settings
Most jumpers and DIP switches on the GUI, FC-FI board
optional slot cards are already at the required settings as
supplied. For example Debug mode is disabled, Boot
mode is disabled, and so on. The default factory set-
tings are marked by * in the following tables.
Some special operational setting should be
implemented under the specific project.
PCB Label
Function
SW1
Master RESET button
SW2
MCPU RESET button
SW3
LIOMCU RESET button
SW4
Alarm RESET Button
SW5
Silence Button
SW6
See Table
SW7
See Table
J1
See Table
J2
See Table
J3
See Table
J4
See Table
J5
See Table
XT1
Terminals: Alarm Relay 1,
Supervised Inputs 1 and 2, Left
External N-Bus/R-Bus
XT2
Terminals: Fault Relay 2, Iso-
lated Input 1, Isolated Input 2,
Right External N-Bus/ R Bus
XT3
Terminals: Relay 3, Loop A,
Loop B
XT4
Terminals: Relay 4, Loop C,
Loop D
XT5
Terminals: Emergency Alarm
Input, Sounder Output 1,
Sounder Output 2, 24V Power
Outp 1, 24V Power Output 2
Table 3: FC-FI DIP Switches and Connector Functions
XT6
Terminals: 24V and 5V Power
for Third Party Cards
XT7
Terminals: 24V and 5V Power
for Third Party Cards)
XT8
Terminals: 24V Power for
FB800 Fuse Board
XT9
Terminals: PSU connection
XT10
Terminals: Battery and Battery
Thermistor connection
XP1
Connector: Black Box front
panel LEDs: Alarm, Fault, Sys-
tem Fault)
XP2
Connector: I2C interface and
5V Power
XP3
Connector: IO-Bus
XP4
Connector: to the internal GUI
XP6
Connector: External N-Bus for
debugging
XP7
Connector: LIOMCU Debug
port RS232
XP8
Connector: MCPU Debug port
RS232
XP9
Connector: COM1 Printer
XP10
Connector: COM2 FCExpress,
FCChecker
XP11
Connector: COM3
Reserved
XP12
Connector: Auxiliary JTAG for
LIOMCU
XP13
Connector: Auxiliary JTAG for
MCPU
XP14
Connector: USB interface
XP15
Connector: ETHERNET inter-
face
XP16
Connector: Internal N-Bus Ser-
vice Channel signals for debug-
ging
XP17
Connector: Internal N-Bus Loop
Channel signals for debugging
XP18
Connector: Auxiliary JTAG for
CPLD
XP19
Connector: interconnection of
external N-Bus interface with
Redundant MCPU slot card
PCB Label
Function
Table 3: FC-FI DIP Switches and Connector Functions