Service Manual
77
Disassembly of right and
left finishing plates
Disassemble the screws as shown with
a
screwdriver and then push upward to
remove the right and left
panels
.
Screw
locations are shown in the drawing.
Disassembly of panel parts
Important: Make sure the power supply to the system is cut off before disassembling and protect all the parts
during disassembly. Do not scratch the outer parts.
Step
Illustration
Handling Instruction
Disassembly of panel
parts
Remove
the
three
screws on the cover
to remove the cover.
Disassembly of electric
al
box
Important: Make sure that the power supply is turned off before disassembling and protect all the parts during
disassembly, especially the components inside the box as these are prone to moisture and impact damage.
Step
Illustration
Handling Instruction
Removal of electrical
box
cover
Remove the three screws as shown in the
picture, then remove the cover.
Disassembly of air deflecting
louvers
Important: Make sure the power supply is cut off before disassembling and protect all the parts during
disassembly, especially the linkages of the air deflecting louvers.
Step
Illustration
Handling Instruction
Disassembly of air
deflecting
louvers
Remove the air deflecting
louvers
from the
air deflecting
louver
support assembly,
and then remove both ends from t
he
stepper motor linkage.
Removal of condensate pan
Important: Make sure the power supply is turned off before disassembling and protect all the parts during disassembly.
Step
Illustration
Handling Instruction
Removal of the
condensate pan
Once the outer cover has been removed,
then the condensate pan can be accessed
and removed.