Service Manual
75
Removal and Installation of
Condensate
Pump
Step
Illustration
Handling Instruction
1. Loosen the screws
holding the condensate pan
Use
a
screwdriver to loosen the
screws
holding the condensate pan in
place.
2. Remove the
condensate
pan
Remove the
condensate
pump and replace
it.
3. Pull out the water outlet
pipe and loosen the
screws
holding the
condensate
pump.
Pull out the water outlet pipe and use
screwdriver to loosen the screws
holding
the
condensate
pump.
4. Take out the pump and
replace it
Take out the pump and replace it
Summary of Contents for DHR18CSB21S
Page 12: ...Service Manual 3 2 Nomenclature ...
Page 47: ...Service Manual 38 Figure 2 7 13 ...
Page 65: ...56 H6 DC fan error Service Manual ...
Page 73: ...64 DHR48CSB21S Service Manual Service Manual ...
Page 92: ...83 ...