Service Manual
9
Model
Indoor unit
DHR36NCB21S
DHR42NCB21S
DHR48NCB21S
Outdoor unit
DHR36CSB21S
DHR42CSB21S
DHR48CSB21S
Capacity
Cooling Capacity
Btu/h
34000(10800~39000) 39500(12000~42500) 48000(20400~50500)
Heating Capacity
Btu/h
41000(9800~49500) 44000(13000~52500) 54500(17500~61500)
Power Input
Cooling
kW
3.28(0.80~4.60)
4.05(0.60~4.70)
4.95(1.30~5.50)
Heating
kW
3.75(0.65~4.80)
4.05(0.69~4.80)
4.60(1.20~5.40)
SEER / HSPF
(Btu/h)/W
16.00/9.00
16.00/9.00
16.00/9.00
Indoor Unit
DHR36NCB21S
DHR42NCB21S
DHR48NCB21S
Power Supply
V/Ph/Hz
208/230V
1Ph
~ 60Hz
208/230V
1Ph
~ 60Hz
208/230V
1Ph
~ 60Hz
Heat Exchange
r
-
Cross Fin Coil
Cross Fin Coil
Cross Fin Coil
Fan
Drive
-
Direct
Direct
Direct
Motor Output
kW
0.15×1
0.15×1
0.25×1
Air Flow
m
3
/h(CFM)
1900(1115)
1900(1115)
2300(1350)
Sound Pressure Level(SS/H/M/L)
dB(A)
54/53/51/46
55/54/52/47
56/55/50/46
Air Filter
-
PP
PP
PP
Condensate
Piping
mm(inch)
Φ17×1.75
(φ0.67×0.07)
Φ17×1.75
(φ0.67×0.07)
Φ17×1.75
(φ0.67×0.07)
Outline Dimensions (W×H×D)
mm(inch)
1420×245×700
(55.9×9.6×27.6)
1420×245×700
(55.9×9.6×27.6)
1700×245×700
(66.9×9.6×27.6)
Net Weight
kg(lb)
48.0(105.8)
50.0(110.3)
59.0(130.1)
Outdoor Unit
DHR36CSB21S
DHR42CSB21S
DHR48CSB21S
Power Supply
V/Ph/Hz
208/230V
1Ph
~ 60Hz
208/230V
1Ph
~ 60Hz
208/230V
1Ph
~ 60Hz
Heat Exchange
r
-
Cross Fin Coil
Cross Fin Coil
Cross Fin Coil
Compressor
Type
-
Rotary
Rotary
Rotary
Power Input
W
4150
4150
4580
Refrigerant
R410A
Control
-
Electronic Expansion
Valve
Electronic Expansion
Valve
Electronic Expansion
Valve
Charge
kg(oz)
3.5(123.5)
3.7(130.5)
4.0(141.1)
Outline Dimensions (W×H×D)
mm(inch)
1107×1100×440
(43.6×43.3×17.3)
958×1349×412
(37.7×53.1×16.2)
958×1349×412
(37.7×53.1×16.2)
Net Weight
kg(lb)
93.0(205.1)
95.0(209.5)
105.0(231.5)
Piping
Connections
Liquid
Inch
Φ3/8
Φ3/8
Φ3/8
Gas
Inch
Φ5/8
Φ5/8
Φ5/8
Max. Length
m(ft)
30(98.4)
50(164.0)
50(164.0)
Max. Height
m(ft)
15(49.2)
30(98.4)
30(98.4)
Note:
Nominal capacities are based on the follow
ing
conditions.
Indoor
Outdoor
Cooling
DB:
80.0
℉ (
26.7
℃
)
WB:
67.0
℉ (
19.4
℃
)
DB:
95.0
℉ (
35.0
℃
)
WB:
75.0
℉ (
23.9
℃
)
Heating
DB:
70.0
℉ (
21.1
℃
)
WB:
60.0
℉ (
15.6
℃
)
DB:
47.0
℉ (
8.33
℃
)
WB:
43.0
℉ (
6.11
℃
)
Piping Length
18k~48k units
25.0ft (
7.6m)
The air volume is measured at the relevant standard external static pressure.
Noise is tested in
a s
emi
-
anechoic room, so it should be slightly higher in the actual operation due to
environmental change.
Summary of Contents for DHR18CSB21S
Page 12: ...Service Manual 3 2 Nomenclature ...
Page 47: ...Service Manual 38 Figure 2 7 13 ...
Page 65: ...56 H6 DC fan error Service Manual ...
Page 73: ...64 DHR48CSB21S Service Manual Service Manual ...
Page 92: ...83 ...