background image

P5415475

 2

Safety Messages

 

Indicates a hazardous situation that, if not avoided, could result in death or 

serious injury.

Indicates a hazardous situation that, if not avoided, could result in minor or 

moderate injury. 

Indicates information considered important, but not hazard-related (for 

example, messages relating to property damage).

General Precautions

To reduce the risk of serious injury or death, read these instructions 

thoroughly and follow all warnings or cautions included in all manuals that 

accompanied the product and are attached to the unit. 

Refer back to these 

safety instructions as needed.

 

This system, including this controller, should be installed by personnel certified by Johnson Controls, 

Inc. Personnel must be qualified according to local, state and national building and safety codes and 

regulations. Incorrect installation could cause leaks, electric shock, fire or an explosion. In areas 

where Seismic Performance requirements are specified, the appropriate measures should be taken 

during installation to guard against possible damage or injury that might occur in an earthquake.  

If the unit is not installed appropriately correctly, injuries may occur because of a falling unit.

 

Use appropriate Personal Protective Equipment (PPE), such as gloves, protective goggles and 

electrical protection equipment and tools suited for electrical operation purposes. 

 

When transporting, be careful when picking up, moving and mounting these units.  

Although the controller may be packed using plastic straps, do not use them for transporting from one 

location to another. Do not stand on or put any material on the controller. 

 

When installing the controller cabling to the units, do not touch or adjust any safety devices inside 

the indoor or outdoor units. All safety features, disengagement, and interlocks must be in place and 

functioning correctly before the equipment is put into operation. If these devices are improperly adjusted 

or tampered with in any way, a serious accident can occur. Never bypass, wire around, or jump-out any 

safety device or switch. 

 

Use only Johnson Controls recommended, provided as standardized, or replacement parts.

 

Johnson Controls shall will not assume any liability for injuries or damage caused by not following steps 

outlined or described in this manual.  Unauthorized modifications to Johnson Controls products are 

prohibited as they…

 

May create hazards which could result in death, serious injury or equipment damage; 

 

Will void product warranties; 

 

May invalidate product regulatory certifications;

 

May violate OSHA standards;

Take the following precautions to reduce the risk of property damage.

 

Do not touch the main circuit board or electronic components in the controller or remote devices. 

Make sure that dust and/or steam does not accumulate on the circuit board.

 

When installing the unit in a hospital or other facility where electromagnetic waves are generated 

from nearby medical and/or electronic devices, be prepared for noise and electronic interference 

Electromagnetic Interference (EMI). Do not install where the waves can directly radiate into the 

electrical box, controller cable, or controller. Inverters, appliances, high-frequency medical equipment, 

and radio communications equipment may cause the unit to malfunction. The operation of the unit 

may also adversely affect these same devices. Install the unit at least 10 ft. (approximately 3m) away 

from such devices.  

 

Locate the wireless controller at a distance of at least three feet (approximately 1m) between the 

indoor unit and electric lighting. Otherwise, the receiver part of the unit may have difficulty receiving 

operation commands. 

Summary of Contents for CIR01

Page 1: ...LIT 12012036 IMPORTANT READ AND UNDERSTAND THIS MANUAL BEFORE USING THIS WIRELESS CONTROLLER KEEP THIS MANUAL FOR FUTURE REFERENCE Operation Installation Manual Wireless Controller CIR01 P5415475...

Page 2: ...have questions please contact your distributor or dealer This manual provides common descriptions basic and advanced information to maintain and service this heat pump air conditioning unit which you...

Page 3: ...evices inside the indoor or outdoor units All safety features disengagement and interlocks must be in place and functioning correctly before the equipment is put into operation If these devices are im...

Page 4: ...maintenance of the unit to the customer according to the information in all manuals that accompanied the system All manuals and warranty information must be given to the user or left near the Indoor...

Page 5: ...ccess channel When installing the power lines do not apply tension to the cables Secure the suspended cables at regular intervals but not too tightly Make sure that the terminals do not come into cont...

Page 6: ...ing Bracket 1 For Controller Battery AAA 1 5V Dry Cell 2 For Power Source of Controller Screw 2 For Fixing Holding Bracket onto Wall Brand Label 1 HITACHI YORK Slide the battery cover toward the arrow...

Page 7: ...hange sequentially through LOW MED HIGH HIGH2 and AUTO Depending on the setting for selecting the function it is possible to set the ON OFF for the Fan Speed AUTO 1 Step 2 Step 7 Step Auto Swing On Sw...

Page 8: ...ectronic type light is used in the room Liquid Crystal Display LCD Indication When viewed from certain angles the LCD can be difficult to read The viewing angle will range from an optimal angle of 60...

Page 9: ...button is pressed 6 Optional Function Setting The display range of the wireless controller can be set following the function to set the indoor unit ATTENTION The settings cannot operate correctly eve...

Page 10: ...ler designated as B Refer to the installation and maintenance or the Operation Manual for each receiver kit or indoor unit setting Depending on the type of the receiver kit or the indoor unit only set...

Page 11: ...is set correctly In the Test Run mode the red light RUN on the receiver kit is turned ON and the green light TIMER flashes 0 5 seconds ON 0 5 seconds OFF Then set the OFF timer for two hours 6 Halt t...

Page 12: ...s Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause un...

Reviews: