898841-UIM-B-0113
Johnson Controls Unitary Products
3
ASSEMBLED OUTDOOR UNIT
The assembled outdoor unit will include the following items which are
located with the unit:
SECTION IV: REQUIRED INSTALLATION
TOOLS (NOT SUPPLIED)
1.
Gauge manifold
2.
Electronic balance for refrigerant charging
3.
Phillips head screwdriver
4.
Knife or wire stripper
5.
Carpenters level
6.
Hammer
7.
Drill
8.
Tube cutter
9.
Tube flaring tool
10. Torque wrench
11. Adjustable wrench
12. Reamer (for de-burring)
13. Vacuum pump (For R410A)
14. Gas leakage detector
SECTION V: SELECTING THE
INSTALLATION LOCATION
INDOOR UNIT (SEE FIGURE 2 FOR INSTALLATION
DIMENSIONS)
1.
Install the unit securely in a place that can bear the weight and
vibration of the unit.
2.
Select a location where the condensate can be easily drained out.
3.
Install in a location where there is enough space to access the unit
for routine maintenance (air filter can be removed for cleaning or
replacement).
4.
Install where airflow is not blocked.
5.
Install in a location for optimized cold or warm air distribution.
6.
Install in a location that's not exposed to direct sunlight.
7.
Install in a location that's at least 3 ft away from a TV and radio to
avoid possible interferences with the operation of the air condi-
tioner/heat pump.
8.
Install in a location that's at least 3 feet away from fluorescent and
incandescent lights to avoid interference with the remote control.
REMOTE CONTROL
1.
Keep the remote control where it is convenient to operate and eas-
ily visible.
2.
Keep the remote control away from children.
3.
When using the I FEEL feature, select a location for the remote
control that's about 4 ft. above the floor.
TABLE 1:
Indoor Parts
Remote Control
1
Flare nut 1/4" for small
line on all size units
except 30K which
uses 5/8".
1
Batteries (AAA)
2
Cable routing guide
with mounting
hardware (18 - 24 kBtu
systems only)
1
Wall mounting bracket
screws
09, 12 & 18 kBtu (5)
24K kBtu (10)
Installation Manual
1
Foam tube insulation
(for condensate line
attached to indoor unit)
1
User’s Information
Manual
1
TABLE 2:
Outdoor Parts
Auxiliary drain hole plugs
(heat pump only)
1 - 3
Drain plug
(heat pump only)
1
Reference
Location
Required
Clearance
A
Clearance between unit and ceiling
6 inches
B
Clearance between unit and floor
6 feet
C / D
Clearance to the right and left of the unit
6 inches
FIGURE 1:
Indoor Clearances
A
D
C
B