www.johnsonandstarley.co.uk

4

3.  

TO LIGHT THE BOILER

If a programmer is fitted refer to seperate instructions for the programming before 

continuing,

3.1 

Check that the electric supply to the boiler is on.

3.2 

Set the mode control to winter usinf ‘K5’.

3.3 

Set the Heating temperature control to ‘max’ using ‘K1’.

3.4 

Check that all external controls, e.g. programmer, room thermostat and cylinder 
thermostat, are ON.

3.5 

The boiler will commence the ignition sequence supplying heat to the central 
heating, if required.

NOTE:  In normal operation the boiler status disply will be.

DISPLAY CODES

 

 

 

Call for heat

 

 

 

Burner on low

     Medium

     High

 

Temperature of supply

4.  

OPERATING FUNCTIONS

 

4.1 

OPERATING THE CENTRAL HEATING

 

When the boiler fire in CH mode it fires for 1 minute, modulating the boiler. The display will flash showing 
the radiator, the small flame and temperature. A flame symbol increases with the demand for heat. Once 
temperature is reached the display will go back to standby.

 

Approximate flow temperatures for the boiler thermostat settings are:

TABLE. 2

Button Setting

CH Flow Temperature °C

Minimum

40°C

Maximum

80°C

FIGURE 3.

Summary of Contents for Quantec 16RK

Page 1: ...y co uk USER S INSTRUCTIONS These instructions are to be left with the User Publication No ZZ 1464 September 2013 QUANTEC REGULAR Kompact High Efficiency Boiler Quantec 16RK G C No 41 416 19 Quantec 2...

Page 2: ...e that the installer has fully completed the Benchmark Checklist on the inside back pages of the installation instructions supplied with the product and that you have signed it to say that you have re...

Page 3: ...ions for use by the heating engineer to the user where specific requirements may occur 1 2 The QuanTec Regular Kompact is a wall mounted room sealed condensing boiler featuring full sequence automatic...

Page 4: ...upplying heat to the central heating if required NOTE In normal operation the boiler status disply will be DISPLAY CODES Call for heat Burner on low Medium High Temperature of supply 4 OPERATING FUNCT...

Page 5: ...he pipe If this fails to remedy the problem the assistance of a Gas Safe Registered Engineer or in IE a Registered Gas Installer RGII should be sought 5 RESET BOILER Press the reset button See Table 1...

Page 6: ...ler E09 valve feed back ERROR Contact installer E12 EEPROM lockout Contact installer E15 Sensor drift lockout Ensure water in heating system Bleed radiators check system pressure Check valves are open...

Page 7: ...valves are open Wait 15 minuets turn power OFF ON Contact installer F13 Remote Reset Lockout Turn power OFF and ON Press Reset Contact Boiler F53 Flue Temperature Sensor error Contact installer GAS LE...

Page 8: ...es johnsonandstarley co uk marketing johnsonandstarley co uk Reception 01604 762881 Sales Spares 01604 707012 Service Warm air upgrade 01604 762881 Warm air upgrade 01604 707011 Johnson Starley Dravo...

Reviews: