9.1 OptiLine Customer Calibration
The T shaped calibration tool supplied with the OptiLine kit is required for checking and
correcting any parallelism disparity between the rear scanner plane and the axis of the ma-
chine wheel shaft to guarantee precision measurement of the tread conicity indices. The
procedure uses this special Calibration Tool supplied in the kit, on whose front surface the
rear laser’s beam must run.
The calibration should be carried out regularly. It is recommended to perform a calibration on
a monthly basis.
To perform the PULL calibration, proceed as follows:
Open the OPTIMA ENTRY screen page as shown below in Figure 51.
Figure 51
Select key F3 to open the OPTIMA PARAMETERS screen page and select key F1, Fig 52.
Figure
Figure 52
35
Install the Calibration Tool so that the blind hole used as a reference faces the outside of the
machine.