Page 7
John Bean BFH 1000 Series Operators Manual
2.1 ELECTRIC INSTALLATION
ANY ELECTRICAL WIRING MUST BE PERFORMED BY LICENSED PERSONNEL.
ALL SERVICE MUST BE PERFORMED BY AN AUTHORIZED SERVICE TECHNICIAN.
Check on the plate of the machine that the electrical specifications of the power source are the same as the
machine. The machine uses 230VAC (+/- 15%), 50-60Hz, 1Ph, 3.2 Ampere.
NOTE:
ANY ELECTRICAL OUTLET INSTALLATION MUST BE VERIFIED BY A LICENSED ELECTRICIAN BEFORE
CONNECTING THE BALANCER.
NOTE:
THIS MACHINE PERFORMS A SELF-TEST ROUTINE ON START-UP. THERE WILL BE A DELAY OF SEV-
ERAL MOMENTS BEFORE UNIT IS READY FOR OPERATION. ANY PROBLEMS DETECTED AT START-
UP WILL RESULT IN THE DISPLAY OF AN ERROR CODE. PROBLEMS DETECTED DURING OPERATION
ARE SAVED TO A LOG FILE WHICH CAN BE RETRIEVED FOR DIAGNOSIS BY A TECHNICIAN.
2.2 SETUP
Every shop has different procedural requirements meaning each machine should be customized to the unique
services performed at that location. Most attributes are set from the Main Function menu. A second “Optima”
menu allows further customization
2.2.1 Customizing the System
A.
Select the “Function” key (F1) from the “Welcome” menu. The Main Function setup screen appears as in
Figure 5.
B.
Press and hold the “F6” button and rotate the wheel to scroll up or down to the desired line item.
C.
Press and hold the “F5” button and rotate the wheel to change selected topic to desired value or function.
D.
When the desired features have been selected, save selections to permanent memory by selecting line item “3”.
Hold the F5 button while rotating the shaft, enter a value of “1”, release to
Save to Permanent Memory.
See
Figure 5a next page for complete menu listing.
E
. Select the “ESC” button on the keyboard to return to the main screen.
Figure 5
Summary of Contents for BFH 1000
Page 2: ...Blank page ...
Page 6: ......
Page 14: ...Page 8 Figure 5a Complete Function Menu listing ...
Page 44: ...NOTES ...
Page 45: ...NOTES ...