Page 9
John Bean BFH 1000 Series Operators Manual
2.2.2 CUSTOMIZING OPTIMA FEATURES
•
From the “Welcome” Screen or Balance Screen, select the “F6” Optima button.
•
Select the “F3” Key to enter the menu used to set the limits required for an Optimization procedure.
•
Set the values for measurement limits as required by the shop in lines 1-4 and 13-16. See Figure 6
D.
Line Item 5 allows the user to select the option of making a profile measurement with each spin or only after
a clamping cycle. Select option “0” (only after clamping) allows a quicker floor to floor time. The unit will then
profile the next wheel assembly after it is clamped. It considers each subsequent spin to be a check spin using
the same parameters and profile.
E.
Advanced Options selection will activate the “Optiline” feature available with the BFH1000 Super. See page
28 for Operation details.
F
. Advanced Spoke Detection will enable a multiple pass spoke counter. When enabled the spoke counter will
attempt to detect spoke in mutiple locations.
G.
Enable or disable Flat Spot Detection. This feature will detect an abnormally worn area of a tire.
H.
Measure Wheel runout in multiple positions if only a wheel is mounted for bent rim diagnosis.
I.
Save the values selected by scrolling down to line item 8, (Save to Memory) while rotating the shaft, enter a
value of “1”, release to
Save to Permanent Memory
NOTE: It is recommended that default values be used until which time the users feel they can customize
the menus for desired results.