5500 ProFlex
11
DEVICE CONFIGURATION
It is of utmost importance that your device is configured in a right way in order to make the
ProFlex installation successful. To do so, follow the below mentioned steps carefully.
1.
Input
1.1
Define the LNB settings (INPUT > LNB > INPUT 1-4)
o
Input
: Sequence number of the input (also indicated on the front
of the actual module)
o
Label
: custom label for each input (e.g. VLow, or ASTRA
19.2VLow
, …)
o
Voltage
: The LNB voltage to select the polarization
13V: Vertical polarization
18V: Horizontal polarization
o
Tone
: LNB tone to select low/high band
ON: high band
OFF: low band
o
DiSEqC
®: control of a DiSEqC® switch (A/B/C/D)
o
Band
: Satellite band
Ku-band
C-band
o
Extended Voltage
: Add 1V to the LNB voltage to compensate the
cable losses for long coaxial cables.
o
Enable
: do not forget to enable the LNB input, this is disabled by
default)
o
Press
APPLY
to confirm the parameters.