Joerns Healthcare Bari10A User & Service Manual Download Page 16

www.joerns.com | [email protected]

Joerns

®

 Bariatric Beds

Bari10A Model

16

d.  Check structural parts for any cracking    
 

(especially welds), bending or hole  

 

 

enlargement.  

e.  Check wiring for proper connections and  
 

damage (fraying, kinking or deterioration).  

 

Report any damage to Joerns Healthcare  

 

Technical Support at 800-966-6662.

 

f.  Check Actuators for correct mounting at 

 

 

attachment points and insure all related pins 

 

are mounted securely and properly to frame.  

 

Actuators are not serviceable. 

If any discrepancies are noted during 

inspection, they must be corrected 

before continuing bed usage. Major 

service and repair must only be 

performed by authorized Joerns 

Healthcare Technical Support, which 

you may contact at 800-966-6662.

General Cleaning 

For low level disinfecting, wipe surfaces with a 

properly prepared detergent/disinfectant. 
Do not use abrasive cleaners. Use damp rag 
only when cleaning around electrical connectors 
and components. 
Actuator surfaces must be cleaned of dust and 
dirt regularly. Do not attempt to clean exposed 

piston rods. Never spray directly on Actuator 

with high-pressure cleaners. 

Storage 

Store in a clean dry area. 

Plug bed Power Cord into grounded hospital-
grade electrical outlet. Actuator Control System 

backup batteries maintain the longest life if kept 
charged and are not allowed to fully discharge. 

Failure to keep Bari10A bed plugged in, will 

discharge backup batteries and shorten their life. 
If storing bed for periods longer than three 

months, remove all Scale System batteries.

1.

2.

3.

1.

2.

3.

4.

Battery Replacement

If Scale System batteries need replacement, 
display will indicate “CHANGE BATTERIES.” 
Remove Battery Cover from Foot Panel to 
access Scale System batteries (Figure 23). 
Then, remove 

all six

 batteries (dispose used 

alkaline batteries per local codes), and replace 

with alkaline D cell batteries. 
Printed circuit board vulnerable to electrostatic 

discharge (ESD). Avoid touching circuit board 

when changing batteries. Battery orientation is 
illustrated on battery holder. 

Cleaning, Inspection 

and Maintenance

Warning

: Disconnect Bari10A Power Cord from 

wall outlet before cleaning. 

Warning

: Do not use power wash or high pressure 

cleaner on 

any

 Bari10A part.

Warning

: Lock all four Casters when cleaning, 

inspecting or performing any maintenance of the 
Bari10A. Lower all Mattress Support Platform 
sections unless necessary for positioning for 
service access. Place all Selective Function 
Lockout switches in 

locked

 position. Disconnect 

Power and Pendant Cords. 

Caution:

 It is critically 

important to lock 

all four

 casters individually.

To achieve maximum usage and longest life 

for your Bari10A bed, follow all warnings and 

cautions within this manual and maintain 

your bed with care, as outlined below. The 

maintenance required will be dictated by 

your bed’s usage and care, which should be 

inspected every six months. 

To optimize bed longevity:

 

a.  Keep bed clean.  
b.  Observe bed usage and operation and    
 

report any discrepancies or problems to   

 

Joerns Healthcare Technical Support at   

 

800-966-6662.

 

c.  Check for loose bolts, nuts or pins, and    

 

report problems. After a week of  

 

 

use, check all bolts for any looseness, and  

 

make sure all pins are in their    

 

 

normal location and fastened.  

1.

2.

1.

2.

Summary of Contents for Bari10A

Page 1: ...Joerns Healthcare User Service Manual Joerns Model Bari10A Bariatric Bed leading bed evolution To avoid injury read user s manual before using bed...

Page 2: ...not be placed in an oxygen enriched environment such as an oxygen tent Use of electrical circuits in an oxygen enriched environment could result in a fire hazard 2 Warning Possible Shock Hazard Unplu...

Page 3: ...maneuverability performance push the bed from the head end To avoid injury to the resident patient and or user do not attempt to move the bed laterally with the steer mode engaged The steer wheel can...

Page 4: ...f long term care beds and a frontrunner in addressing this critical issue Joerns Healthcare can offer you the expertise assistance and products to bring your facility into compliance Joerns Compliance...

Page 5: ...ra 8 length for taller residents patients 18 3 4 to 33 3 4 Travel Range Integrated Scale System for resident patient weight monitoring Head and Foot End Side Rails Assist Devices Side Rails on Head an...

Page 6: ...Lock for all functions to keep bed from accidentally operating using battery backup Note To avoid electric shock always plug bed into properly grounded hospital grade receptacle Actuator battery backu...

Page 7: ...port Platform Release Lever Up Hold Emergency Release handle Up until Mattress Support Platform lowers to desired position Release handle if you need to stop descent 1 1 1 2 7 Figure 4 Bari Selective...

Page 8: ...s rotate switch until it clicks into position Side Rails Assist Devices Bari10A has one Head end Side Rail and one Foot end Side Rail on both sides of bed Figure 7 Side Rails are attached and operated...

Page 9: ...owest position with the siderails fully raised and locked when moving the bed with a resident patient in it For best maneuverability performance push the bed from the head end Warning 5th wheel must b...

Page 10: ...p process Slide the Frame Extender out first by pulling out the latch knob on the side of the bed frame Figure 14 Begin carefully sliding the extender out and release the latch knob as soon as the ext...

Page 11: ...t to lock all four casters individually to prevent unintended bed movement Always plug bed back into power outlet so that it is continuously charging Accessories Mattress Bari10A Bed may be equipped w...

Page 12: ...www joerns com info joerns com Joerns Bariatric Beds Bari10A Model 12 F Figure 18...

Page 13: ...ng Conditions Ambient Temperature 20 C to 30 C Relative Humidity 10 to 95 Non Condensing Storage and Shipping Conditions Ambient Temperature 30 C to 50 C Relative Humidity 10 to 95 Non Condensing 1 2...

Page 14: ...will lose all stored resident patient s weight history Pressing Weight Mode button will switch back to the Weight Mode allowing you to view resident patient s total weight again Caution If you do not...

Page 15: ...12 months or as your maintenance policy requires Electrostatic Discharge ESD Integrated circuits and semiconductors on printed circuit boards may be damaged by electrostatic discharge ESD Be sure to...

Page 16: ...teries 1 2 3 1 2 3 4 Battery Replacement If Scale System batteries need replacement display will indicate CHANGE BATTERIES Remove Battery Cover from Foot Panel to access Scale System batteries Figure...

Page 17: ...Use Super Lube synthetic grease or equivalent Oiling Points Keep pins and bolts oiled sample indicated by arrows in Figure 24 Oil hinge points sample indicated by arrows in Figure 25 Grease Points For...

Page 18: ...d may be damaged Check cord for damage If cord is damaged discontinue bed usage until cord is replaced 1 2 3 4 If Adjustment Only partially occurs stops and beeps Battery may be low Plug bed into powe...

Page 19: ...ctions may require two hands to apply equal pull force Contact Joerns Healthcare Technical Support at 800 966 6662 1 2 Mattress Support Platform sections do not articulate Pendant Control operation Se...

Page 20: ...www joerns com info joerns com Joerns Bariatric Beds Bari10A Model 20 Appendix A Actuator Wiring Diagram...

Page 21: ...www joerns com info joerns com Joerns Bariatric Beds Bari10A Model Appendix B Scale System Wiring Diagram 21...

Page 22: ...www joerns com info joerns com Joerns Bariatric Beds Bari10A Model 22 Notes...

Page 23: ...www joerns com info joerns com Joerns Bariatric Beds Bari10A Model 23 Notes...

Page 24: ...mal use These parts such as DC batteries are not covered under the one year warranty but are covered for 90 days after date of delivery Joerns Healthcare s obligation under this warranty is limited to...

Reviews: